CHARTVIEW CYCLE NUMBER AND EXPIRATION DATE
ChartView database is revised every 14 days. Charts are still viewable during a period that extends from the
cycle expiration date to the disables date. ChartView is disabled 70 days after the expiration date and is no
longer available for viewing. When turning on the system, the Power-up Page displays the current status of the
ChartView database. See the table below for the various ChartView Power-up Page displays and the definition
of each.
Figure 8-46 Power-up Page, ChartView Database
ChartView Database
Power-up Page Display
Definition
Blank Line. system is not configured for ChartView. Contact a Garmin‑
authorized service center for configuration.
System is configured for ChartView but no chart database is installed.
Contact Jeppesen for a ChartView database.
Normal operation. ChartView database is valid and within current
cycle.
ChartView database is within 1 week after expiration date. A new cycle
is available for update.
ChartView database is beyond 1 week after expiration date, but still
within the 70 day viewing period.
ChartView database has timed out. Database is beyond 70 days after
expiration date. ChartView database is no longer available for viewing.
System time is not available. GPS satellite data is unknown or the
system has not yet locked onto satellites. Check database cycle number
for effectivity.
System is verifying chart database when new cycle is installed for the
first time.
After verifying, chart database is found to be corrupt. ChartView is not
available.
Table 8-2 ChartView Power-up Page Annunciations and Definitions