4.3 Maintenance Intervals
Table 4-1 shows systems and items, installed by this STC, which must undergo tests or checks
at specific intervals. If the interval is shown to be in flight time as well as calendar months, the
first interval reached should be used as the limit.
Those inspections that are based on flight time or calendar elapsed time or cycles shall have
specific intervals stated in Table 4-1.
Table 4-1
– Maintenance Intervals
Item
Description/Procedure
Manual
Section No.
Interval
Equipment electrical
Bonding Test
Verify bonding of GMC 507 rack (if
installed), GMC 507 (if installed without
rack), GSA 28 mounting brackets, and
any associated bonding components
4.5
Following removal
and replacement of
the racks or brackets
AND
Every 2000 flight
hours or ten years,
whichever is first
Equipment Bonding Visual
Inspection
– suspected
lightning strike
Inspection of bonding Components
Table 4-3
At any suspected or
actual lightning
strike
GFC 500 Equipment
Visual Inspection
Visual inspection of GFC 500
components
4.4
At every annual
inspection
Disconnect Tone and
Sonalert Test
Functional test of Audio output and/or
Sonalert
4.6
At every annual
inspection
GSA 28 Servos
Removal and Replacement
6.2
On Condition
GMC 507 Autopilot Mode
Controller
Removal and Replacement
6.1
On Condition
Servos, Servo Control
Cables and associated
hardware
Visual Inspection
Table 4-2