190-00303-05
GIA 63 Installation Manual
Rev. Y
Page 4-31
4.7.2.8 ILS Energize
INACTIVE: Floating (can be pulled up to externally sourced Vout in the range 0
≤
Vout
≤
33VDC)
Leakage current in the INACTIVE state is typically
≤
10 uA to ground
ACTIVE: Vout
≤
0.5VDC with
≤
20 mA sink current
Sink current must be externally limited to 20 mA max
Table 4-30. ILS Energize
Pin Name
Connector
Pin
I/O
ILS ENERGIZE*
P602
29
Out