Page 4-2
G300 Installation Manual – GSU 73
Revision A
190-00921-01
4.1.1
Features Summary
Air Data
Interfaces
Pressure
Altitude CAN
(1)
Density Altitude
RS-232 (2 TX/2 RX)
Vertical Speed
ARINC 429 (4 RX/2 TX)
Mach
Number
OAT
Probe
(GTP
59)
Indicated Airspeed
Magnetometer (GMU 44) (1 RS-232 TX/ 1 RS-485 RX)
True Airspeed
AHRS
Engine/Airframe
Magnetic Heading
28 Analog inputs, including those allocated as per below:
Pitch
Angle
Dedicated
Ammeters
(2)
Roll Angle
Constant Current Source Capability (6)
Linear Accelerations
Divider Circuits to handle large input voltages (12)
Pitch, Roll, Yaw Rotation Rates
Frequency Counter Inputs (4)
Discrete
I/O
(4
In/2
Out)
4.2
Electrical Specifications
Table 4-1. GSU 73 Supply Specifications
Characteristic
Specification
Input Voltage Range
9-29 Vdc
Power Input
1.75 Amp @ 14 Vdc (Max)