400 SERIES INSTALLATION MANUAL
Page 1-3
190-00140-02
Rev
Q
1.3.2 General
Specifications
Operating Temperature Range
-20
q
C to +55
q
C. For more details see Environmental
Qualification Form.
Humidity
95% non-condensing
Altitude Range
-1,500 ft to 50,000 ft
Input Voltage Range (GPS 400)
11 to 33 V
DC
Input Voltage Range
GNS 430 (011-00280-00) and
GNC 420 (011-00506-00)
22 to 33 V
DC
Input Voltage Range
GNS 430 (011-00280-10, -30)
GNC 420 (011-00506-10, -30)
11 to 33 V
DC
GNS 430 (A) (011-00836-00,-10)
GNC 420 (A) (011-00837-00,-10)
28 V
DC
Power Requirements—P4001
(GPS 400 Main Connector)
0.72 A @ 27.5 V
DC
________or
1.44 A @ 13.75 V
DC
Power Requirements—P4001
(GNC 420 Main Connector)
1.5 A @ 27.5 V
DC
(maximum)
Power Requirements—P4001
(GNS 430 Main Connector)
1.5 A @ 27.5 V
DC
(maximum)
Power Requirements—P4002
(COM Connector)
GNS 430 (011-00280-00)
GNS 430A (011-00836-00, -10)
and
GNC 420 (011-00506-00)
GNC 420A (011-00837-00, -10)
15 mA @ 27.5 V
DC
(not transmitting);
3.0 A @ 27.5 V
DC
(transmitting)
Power Requirements—P4002
(COM Connector)
GNS 430 (011-00280-10, -30)
and GNC 420 (011-00506-10)
15 mA @ 27.5 V
DC
(not transmitting);
3.0 A @ 27.5 V
DC
(transmitting)_______or
10 mA @ 13.75 V
DC
(not transmitting);
6.0 A @ 13.75 V
DC
(transmitting)
Superflag Power Requirements
500 mA max. per superflag output @ 27.5 V
DC.
1.0 A max. @ 27.5 V
DC
on P4001 (Main Superflags).
1.0 A max. @ 27.5 V
DC
on P4006 (VOR/LOC, G/S
Superflags).
Software
RTCA DO-178B level C
Environmental Testing
RTCA DO-160C.
For more details see Environmental Qualification Forms.
1.3.3 GPS
Specifications
Regulatory Compliance
TSO C129a, RTCA DO-208
Acquisition Time
a) Search-the-Sky (without almanac, without initial position
or time): 5 minutes
b) AutoLocate™ (with almanac, without initial position or
time): 5 minutes
c) Cold Start (position known to 300 nm, time known to 10
minutes, with valid almanac): 45 seconds
d) Warm Start (position known to 10 nm, time known to 10
minutes, with valid almanac and ephemeris): 15 seconds
Max Velocity
1000 kts.
Dynamics
6 g
Summary of Contents for GNC 420
Page 8: ...Page vi 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 This page intentionally left blank ...
Page 28: ...Page 3 8 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 This page intentionally left blank ...
Page 78: ...Page A 8 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 This page intentionally left blank ...
Page 80: ...Page B 2 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 ...
Page 81: ...400 SERIES INSTALLATION MANUAL Page B 3 190 00140 02 Rev Q ...
Page 82: ...Page B 4 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 ...
Page 83: ...400 SERIES INSTALLATION MANUAL Page B 5 190 00140 02 Rev Q ...
Page 84: ...Page B 6 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 ...
Page 85: ...400 SERIES INSTALLATION MANUAL Page B 7 190 00140 02 Rev Q ...
Page 86: ...Page B 8 400 SERIES INSTALLATION MANUAL Rev Q 190 00140 02 ...
Page 87: ...400 SERIES INSTALLATION MANUAL Page B 9 190 00140 02 Rev Q ...