Post-Installation Configuration & Checkout
GNS 480 (CNX80) Installation Manual560-0982-01 Rev A
3-27
3.3.1.2 Input Monitor Function
The Input Monitor Function monitors the external inputs to the GNS 480 and displays the data currently
being received. Press the
INPUT
smart key in the Ground Maintenance mode to reach the Interface
Monitor Function, as shown in Figure 3-27. The display will show the status of the connected interfaces.
Figure 3-27 - Interface Monitor Function Display - Page 1
This page displays activity on each of the ARINC 429 inputs, and the state of each of the discrete inputs.
Press the
NEXT
line select key to show the next page, which is shown in Figure 3-28.
Figure 3-28 - Interface Monitor Function Display - Page 2
This page displays activity on each of the serial inputs, and allows the serial data that is being received
on a particular input to be monitored. Turn the large, outer knob to select the input to be monitored. The
currently selected serial channel is indicated with a green background. The window on the lower half of
the screen displays the last 100 characters that have been received. To stop the update of the data in the
window press the
PAUSE
line select key, which will then become the
RUN
line select key. To start the
update of the data press the
RUN
line select key.
Press the
NEXT
line select key to show the next page, which is shown in Figure 3-29.
Summary of Contents for GNS 480
Page 1: ...GNS 480 CNX80 Color GPS Nav Com Installation Manual September 2004 560 0982 01 Rev A...
Page 10: ...Table of Contents viii 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 126: ...Periodic Maintenance 6 2 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 150: ...Appendix D Interconnect Diagrams D 2 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 185: ......
Page 186: ......