Post-Installation Configuration & Checkout
3-2
560-0982-01 Rev A
GNS 480 (CNX80) Installation Manual
second page
Figure 3-1 - Ground Maintenance Mode Display
3.2.1 S
ETUP
F
UNCTION
The SETUP function allows the custom configuration of the GNS 480 for each individual installation.
The SETUP function allows the installer to configure the serial and ARINC 429 ports, calibrate the
resolver head (if installed), calibrate the baro potentiometer (if installed), and set COM parameters.
3.2.1.1 Serial
Ports
While on the Ground Maintenance SETUP menu page, press the
SERIAL PORTS
line select key to
change the serial port settings. The serial port setup page is shown in Figure 3-2.
Figure 3-2 - Serial Port Setup Page
Push the small, inner knob in to enter the editing mode. The first editable item will be highlighted. Use
the large, outer knob to select the next or previous editable data field and turn the small, inner knob to
change the current setting. Set each serial port according to the installation, and leave unused ports set to
NONE. Either press the small, inner knob in again or press the
MENU/ENTER
key to save the settings.
Press the
SETUP
or
BACK
smart key to return to the Ground Maintenance SETUP menu. The
configuration options for the serial input ports and output ports are shown in Table 3-1.
Summary of Contents for GNS 480
Page 1: ...GNS 480 CNX80 Color GPS Nav Com Installation Manual September 2004 560 0982 01 Rev A...
Page 10: ...Table of Contents viii 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 126: ...Periodic Maintenance 6 2 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 150: ...Appendix D Interconnect Diagrams D 2 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 185: ......
Page 186: ......