500W Series Installation Manual
Page 5-25
190-00357-02
Rev. D
5.4 Ground Checks (Configuration Mode)
5.4.1
Main Indicator (Analog Only)
NOTE
If the GNS 500W Series unit is interfaced to an electronic HSI and the main indicator
analog output is not used, this check is not required.
If the GNS 500W Series unit is interfaced to an analog indicator on the main CDI/OBS, perform the
following steps:
1.
Go to the MAIN CDI / OBS CONFIG page.
2.
Verify correct operation of the lateral deviation, flag and TO/FROM flag using the
corresponding selections.
3.
Verify correct operation of the vertical deviation and flag using the corresponding selections.
4.
Verify correct operation of the OBS knob using the SELECTED COURSE display. At 30°
increments around the OBS card, ensure that the indicated value is within 2° of the value set on
the indicator.
5.4.2
VOR/ILS Indicator (GNS 530W Only)
If the GNS 530W unit is interfaced to an analog indicator on the VOR/ILS Indicator output, perform the
following steps:
1.
Go to the VOR / LOC / GS CDI configuration page.
2.
Verify correct operation of the lateral deviation, flag and TO/FROM flag using the
corresponding selections.
3.
Verify correct operation of the vertical deviation and flag using the corresponding selections.
5.4.3
Discrete Inputs and Annunciator Outputs Checkout
If the GNS 500W Series unit is connected to external annunciators/systems or external switches, perform
the following steps:
1.
Go to the MAIN DISCRETE I/O page.
2.
For each external switch that is connected, exercise the switch and use the EXTERNAL SWITCH
STATE section to verify that the input is functioning correctly.
3.
For each annunciator output that is connected to an external system or annunciator, toggle the output
ON (corresponding box is filled/green) and OFF (corresponding box is not filled/blue) using the
DISCRETE TOGGLE field. Verify that the appropriate external annunciator illuminates when the
output is set to ON and extinguishes when the output is set to OFF. If the output is not connected to
an annunciator but provides an input to another system, verify that the other system receives the
signal.
Summary of Contents for GNS 530W
Page 2: ...500W Series Installation Manual 190 00357 02 Rev D...
Page 130: ...Page 7 4 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 132: ...Page 8 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 134: ...Page A 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 136: ...Page B 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 137: ...500W Series Installation Manual Page C 1 190 00357 02 Rev D Appendix C RESERVED...
Page 138: ...Page C 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 148: ...Page E 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 150: ...Page F 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 160: ...Page G 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 162: ...Page H 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 188: ...Page H 28 500W Series Installation Manual Rev D 190 00357 02 Figure H 16 GTX 330 Interconnect...
Page 194: ...Page H 34 500W Series Installation Manual Rev D 190 00357 02 Figure H 20 RMI OBI Interconnect...
Page 198: ...Page H 38 500W Series Installation Manual Rev D 190 00357 02 Figure H 24 TAWS Interconnect...
Page 211: ...500W Series Installation Manual Page H 51 190 00357 02 Rev D Figure H 33 Switches Interconnect...
Page 215: ......
Page 216: ......