500W Series Installation Manual
Page 5-33
190-00357-02
Rev. D
7.
Using a VOR test set verify that the CDI deviation on the SN3308 is displayed correctly.
5.5.7.2.2 Two 500W Series Units / One SN3308
The checkout for two 500W Series units also applies to one 400W Series unit and one 500W Series unit.
1.
Remove power from the second (no. 2) 500W Series unit.
2.
Cycle power to the first GNS 500W Series unit and acknowledge the prompts until it gets to the
self test page (see Section 5.5.1).
3.
Select GPS1 as the navigation source by pressing the NAV key on the SN3308.
4.
Ensure that the SN3308 is receiving valid heading.
NOTE
The Vertical Deviation Indication will not be displayed unless the SN3308 is receiving
valid heading.
5.
While the first GNS 500W Series unit is displaying the self test page, verify that the SN3308 is
displaying the following data from GPS1.
•
Course Deviation: Half-scale left deviation, TO indication, flag pulled
•
Vertical Deviation: Half-scale up deviation, flag pulled
•
Active Waypoint: GARMN
6.
On the first GNS 500W Series unit verify that an OBS value is displayed (and not dashed out).
7.
Acknowledge the self test on the first GNS 500W Series unit by pressing the ENT key.
8.
Select VLOC on the first GNS 500W Series unit and verify that the SN3308 displays NAV 1 or
NAV 2 (depending on what navigation source the GNS 530W is).
9.
Using a VOR test set verify that the CDI deviation on the SN3308 is displayed correctly.
10.
Remove power to the first 500W Series unit and apply power to the second GNS 500W Series
unit and acknowledge the prompts until it gets to the self test page (see Section 5.5.1).
11.
Select GPS2 by pressing the NAV key on the SN3308.
12.
Repeat steps 4-9 with the second GNS 500W Series unit.
5.5.7.3 Sandel SN3500 Interface Check
If a Sandel SN3500 EHSI has been connected to a 500W Series unit, the interface should be verified as
described in this section.
1.
Cycle power to the GNS 500W Series unit and acknowledge the prompts until it gets to the self
test page (see Section 5.5.1).
2.
Ensure that the SN3500 is receiving valid heading.
NOTE
The Vertical Deviation Indication will not be displayed unless the SN3500 is receiving
valid heading.
Summary of Contents for GNS 530W
Page 2: ...500W Series Installation Manual 190 00357 02 Rev D...
Page 130: ...Page 7 4 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 132: ...Page 8 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 134: ...Page A 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 136: ...Page B 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 137: ...500W Series Installation Manual Page C 1 190 00357 02 Rev D Appendix C RESERVED...
Page 138: ...Page C 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 148: ...Page E 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 150: ...Page F 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 160: ...Page G 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 162: ...Page H 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 188: ...Page H 28 500W Series Installation Manual Rev D 190 00357 02 Figure H 16 GTX 330 Interconnect...
Page 194: ...Page H 34 500W Series Installation Manual Rev D 190 00357 02 Figure H 20 RMI OBI Interconnect...
Page 198: ...Page H 38 500W Series Installation Manual Rev D 190 00357 02 Figure H 24 TAWS Interconnect...
Page 211: ...500W Series Installation Manual Page H 51 190 00357 02 Rev D Figure H 33 Switches Interconnect...
Page 215: ......
Page 216: ......