500W Series Installation Manual
Page G-5
190-00357-02
Rev. D
G.12 CDI/HSI Source Selection Annunciators
An external CDI/HSI Source Selection Annunciation or external GPS annunciations may be required for
some installations – see Section 2.5.1.1 for additional information describing when external annunciation
is required. The following indicators and indicator/switches are suitable for external annunciation:
Manufacturer Part
Number
Type
Notes
Staco Switch
992561-1241762200
Indicator
14VDC Indicator
Staco Switch
992561-1241862200
Indicator
28VDC Indicator
Vivisun
95-40-17-B6-AW724
Indicator
28VDC Indicator (can be converted to
14VDC operation by replacing four
28VDC lamps with 14VDC lamps P/N 14-
113).
Vivisun
95-45-11-B6-AW724
Indicator/Switch
28VDC Indicator with momentary switch
(can be converted to 14VDC operation by
replacing qty 4 28VDC lamps with
14VDC lamps P/N 14-113).
Mid-Continent MD41-1408A
MD41-1404A
MD41-1418A
MD41-1414A
MD41-1468A
MD41-1478A
MD41-1464A
MD41-1474A
MD41-1470
MD41-1484W
MD41-1488W
Indicator/Switch/
GPS
Annunciations
Both 14VDC and 28VDC indicators (refer
to Mid-Continent documentation for
availability of switch functions on each
unit)
Vendor Contact Information (provided for convenience only):
•
Staco Switch, 1139 Baker Street Costa Mesa, CA 92626
Phone: (877) STACO4U
•
Vivisun Aerospace Optics, 3201 Sandy Lane Fort Worth, Texas 76112
Phone: (888) VIVISUN
•
Mid-Continent Instrument Co Inc., 9400 E. 34
th
Street N., Wichita, KS 67226, Phone: (316) 630-0101
G.13 Multifunction
Displays
Manufacturer Model Data
Format
Notes
Garmin
MX20
RS-232
“Avtn no alt” format for MX20 version 5.5
and earlier.
“Aviation” format for MX20 version 5.6
and later. (MX20 will not accept GPS
altitude even though it is part of “Aviation”
Format).
GMX 200
RS-232
“Aviation” format
EX500
P/N 700-00007-( )
ARINC 429
MFD software P/N 530-00193-( ) or later
is required
Avidyne
EX5000
P/N 700-00004-( )
or
P/N 700-00030-( )
ARINC 429
MFD software P/N 530-00195-( ) or later
is required
Summary of Contents for GNS 530W
Page 2: ...500W Series Installation Manual 190 00357 02 Rev D...
Page 130: ...Page 7 4 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 132: ...Page 8 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 134: ...Page A 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 136: ...Page B 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 137: ...500W Series Installation Manual Page C 1 190 00357 02 Rev D Appendix C RESERVED...
Page 138: ...Page C 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 148: ...Page E 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 150: ...Page F 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 160: ...Page G 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 162: ...Page H 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 188: ...Page H 28 500W Series Installation Manual Rev D 190 00357 02 Figure H 16 GTX 330 Interconnect...
Page 194: ...Page H 34 500W Series Installation Manual Rev D 190 00357 02 Figure H 20 RMI OBI Interconnect...
Page 198: ...Page H 38 500W Series Installation Manual Rev D 190 00357 02 Figure H 24 TAWS Interconnect...
Page 211: ...500W Series Installation Manual Page H 51 190 00357 02 Rev D Figure H 33 Switches Interconnect...
Page 215: ......