Page 5-16
500W Series Installation Manual
Rev. D
190-00357-02
5.3.12 VOR/LOC/GS CDI Page (GNS 530W Only)
Select the VOR/LOC/GS CDI page (see Figure 5-15). This
page allows you to verify and calibrate the CDI outputs, both
lateral (LAT) and vertical (VERT) from the
VOR/LOC/Glideslope receiver, as well as the OBS resolver
input to the VOR receiver. It also allows you to select the
format for DME tuning data. Using the controls on the GNS
530W front panel, make the selections below and verify the
interfaces as appropriate:
NOTE
The LAT, VERT, and SELECTED COURSE configurations only apply to installations
where a CDI/HSI is connected to the VOR/LOC/GLIDESLOPE pins on connector
P5006.
CDI (LAT/VERT)
Selection Verify
That:
Max left
The CDI is “pegged” to the left.
Full left
The CDI is deflected full scale to the left.
Std. left
The CDI is deflected left of center.
Center
The CDI is centered.
Std. right
The CDI is deflected right of center.
Full right
The CDI is deflected full scale to the right/down.
Max right
The CDI is “pegged” to the right/down.
NAV FLAG (LAT/VERT)
Selection Verify
That:
Hide
The LAT/VERT flag is hidden.
View
The LAT/VERT flag is in view.
SPR-FLG (LAT/VERT)
Selection Verify
That:
Hide
The LAT/VERT superflag is hidden.
View
The LAT/VERT superflag is in view.
TO-FROM (LAT)
Selection Verify
That:
FROM
The FROM flag is in view.
Hide
The TO/FROM flag is hidden.
TO
The TO flag is in view.
SELECTED COURSE
Select 150° on the CDI/HSI that is connected to the 500W Series unit VOR/LOC/GS OBS inputs. The
SELECTED COURSE field should indicate near to 150° and a Calibrate to 150°? field appears.
Selecting this field calibrates the 500W Series unit to match the input source. Verify OBS operation by
checking that the course displayed on the 500W Series unit is within 2° of the selected course. Do this at
30° intervals around the OBS card.
Figure 5-15. VOR/LOC/GS CDI Page
Summary of Contents for GNS 530W
Page 2: ...500W Series Installation Manual 190 00357 02 Rev D...
Page 130: ...Page 7 4 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 132: ...Page 8 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 134: ...Page A 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 136: ...Page B 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 137: ...500W Series Installation Manual Page C 1 190 00357 02 Rev D Appendix C RESERVED...
Page 138: ...Page C 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 148: ...Page E 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 150: ...Page F 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 160: ...Page G 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 162: ...Page H 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 188: ...Page H 28 500W Series Installation Manual Rev D 190 00357 02 Figure H 16 GTX 330 Interconnect...
Page 194: ...Page H 34 500W Series Installation Manual Rev D 190 00357 02 Figure H 20 RMI OBI Interconnect...
Page 198: ...Page H 38 500W Series Installation Manual Rev D 190 00357 02 Figure H 24 TAWS Interconnect...
Page 211: ...500W Series Installation Manual Page H 51 190 00357 02 Rev D Figure H 33 Switches Interconnect...
Page 215: ......
Page 216: ......