Setting the Anchor Drag Alarm
You can set an alarm to sound if you have moved outside an allowable radius you set when configuring the
alarm.
WARNING
The anchor drag alarm is a tool for situational awareness only, and may not prevent grounding or collisions in
all circumstances. You are responsible for the safe and prudent operation of your vessel, for remaining aware
of your surroundings, and for using safe judgement on the water at all times. Failure to heed this warning could
result in property damage, serious personal injury, or death.
CAUTION
The Beeper setting must be turned on to make alarms audible (
Sounds and Display Settings, page 176
). Failure
to set audible alarms could lead to injury or property damage.
1 Select
> Alarms > Navigation > Anchor Drag.
2 Select Alarm to turn on the alarm.
3 Select Set Radius, and select a distance on the chart.
4 Select Back.
System Alarms
Select
> Alarms > System.
Clock
Sets an alarm clock.
Unit Voltage: Sets an alarm to sound when the battery reaches a specified low voltage.
GPS Accuracy: Sets an alarm to sound when the GPS location accuracy falls outside the user-defined value.
Sonar Alarms
WARNING
The sonar alarms feature is a tool for situational awareness only and may not prevent grounding in all
circumstances. It is your obligation to ensure safe operation of the vessel.
CAUTION
The Beeper setting must be turned on to make alarms audible (
Sounds and Display Settings, page 176
). Failure
to set audible alarms could lead to injury or property damage.
NOTE: Not all options are available on all transducers.
From an applicable sonar view, select Options > Sonar Setup > Alarms.
You can also open the sonar alarms by selecting
> Alarms > Sonar.
Shallow Water: Sets an alarm to sound when the depth is less than the specified value.
Deep Water: Sets an alarm to sound when the depth is greater than the specified value.
FrontVü Alarm: Sets an alarm to sound when the depth in front of the vessel is less than the specified value,
which can help you avoid running aground (
Setting the Garmin FrontVü Depth Alarm, page 93
). This alarm is
available only with Panoptix Garmin FrontVü transducers.
Water Temp.: Sets an alarm to sound when the transducer reports a temperature that is 2°F (1.1°C) above or
below the specified temperature.
Contour: Sets an alarm to sound when the transducer detects a suspended target within the specified depth
from the surface of the water and from the bottom.
Fish: Sets an alarm to sound when the device detects a suspended target.
•
sets the alarm to sound when fish of all sizes are detected.
•
sets the alarm to sound only when medium or large fish are detected.
•
sets the alarm to sound only when large fish are detected.
Device Configuration
183
Summary of Contents for GPSMAP 9 3 Series
Page 1: ...GPSMAP OWNER SMANUAL 12x3 9x3 7x3...
Page 14: ......
Page 221: ......
Page 222: ...support garmin com GUID 3E67C80C 0812 4EEC BC60 699751B9CF6F v4 January 2024...