Installing Locking Rings on the Cables
Before you install locking rings on the cables, you must route the cables.
To help make the cable-routing process easier, the locking rings are packaged separately from the cables. Each
locking ring is packaged in a small bag with a number on the label for easy identification.
1 Separate the two halves of the locking ring .
2 Align the two halves of the locking ring over the cable and snap them together.
3 Insert the o-ring into the end of the connector.
Transducer Wiring Diagrams
NOTICE
Connecting the high-frequency wires to the low-frequency terminal block, or the low-frequency wires to the
high-frequency terminal block, damages the device and the transducer.
You can use these diagrams to identify the connection points for your transducer wires on the GSD 26 terminal
block. Locate your CHIRP/spread spectrum transducer model in the wiring color tables (
) for more information.
The outer shield wire must connect to one of the two screw posts below the terminal block using the included
ring crimp terminal. When connecting two single-element transducers, you must connect the second transducer
to the duplicate set of connections on the right side of the terminal block.
TIP: The primary transducer cable wire housing covers the wiring bundles. To identify the wiring groups in the
bundles more easily, you can remove up to an inch of the cable housing.
6
GSD 26 Installation Instructions