GTN 625/635/650 TSO Installation Manual
190-01004-02
Page 6-56
Rev. F
6.10.10 Altitude Encoder or Air Data Computer Check
The GTN can receive altitude data from an external
source. This check verifies that the GTN is receiving
data from these sources. Ensure that the GTN is
powered on and in configuration mode. If the
following steps do not perform correctly, check the
electrical connections () and configuration setup
(Section 6.6.2) for the interfaced Altitude Encoder/
ADC.
1. Access the Main Data Inputs page, as shown
in Figure 6-58, by touching the ‘Main Data
Inputs’ key on the GTN Diagnostics page.
2. Touch the ‘Down’ key to scroll to the Pressure Altitude data display.
3. If there are multiple altitude sources providing data to the GTN, remove power from all but one
source.
4. Verify that Pressure Altitude is being displayed and agrees with the active altitude source.
NOTE
After applying power to an altitude source it may take several minutes to warm up. During
the warm-up period the Pressure Altitude display on the GTN will be dashed out.
5. If there are multiple altitude sources, remove power from the currently active source and apply
power to another source that has not been checked.
6. Repeat steps 2-4 until all available sources have been checked.
6.10.11 AHRS/IRU Interface Check
The GTN can receive heading data from an external source. This check verifies that the GTN is receiving
data from these units. Ensure the GTN is powered on and in configuration mode. If the following steps do
not perform correctly, check the electrical connections and configuration setup for the interfaced AHRS/
IRU.
1. Access the Main Data Inputs page, as shown in Figure 6-58, by touching the ‘Main Data Inputs’
key on the GTN Diagnostics page.
2. Scroll to the Heading data display.
NOTE
If a Sandel EHSI or an ARINC 429 EFIS is also installed, ensure that it is turned off so
that it does not supply heading to the GTN. Verify that the HDG field displays valid
heading data.
3. Remove power from the heading source and verify that the magnetic heading field is dashed out.
Figure 6-58. Main Data Inputs Page
Summary of Contents for GTN 625
Page 1: ...190 01004 02 February 2013 Revision F GTN 625 635 650 TSO Installation Manual ...
Page 2: ......
Page 242: ...GTN 625 635 650 TSO Installation Manual 190 01004 02 Page D 36 Rev F Figure D 24 Reserved ...
Page 250: ...GTN 625 635 650 TSO Installation Manual 190 01004 02 Page D 44 Rev F Figure D 32 Reserved ...
Page 253: ......
Page 254: ......