4
Version 1.0
Section 2
Software and Configuration Loading
This section will provide the steps necessary to target load the software and configuration into
GTS 8000 after replacement.
Note:
Anytime that software or configurations are being loaded, all three displays, and both
touch controllers must be in configuration mode.
Note: Ensure that you have completed the steps contained in Section 1.
•
GTS 8000 (TCAS I or TCAS II Processor)
Note that TCAS II functions are through an unlock card. See section 4.
•
When the GTS 8000 is replaced, then software and configuration loading is required.
1)
Pull the following circuit breakers:
L PFD
MFD
R PFD
L Touch Control
R Touch Control
2)
Insert the 010-01121-10 software loader card into the upper slot of PFD 1.
3)
Turn on aircraft power.
4)
Press and hold the right knob on the left GTC and push the L Touch Control circuit
breaker in.