Page 6
688 Manual
The PERMIT diagnostic LED will light when the controller is in
permit and is connected to either an optic or thermistor rack. It
will not illuminate if the controller is not connected, since the rack
is the controller power source.
WARNING: To maintain overfill protection, the operator
MUST verify float movement of the
S
EE
L
EVE
L
TM
(or
S
EE
L
EVE
L
S
PECIAL
TM
) at the start of loading each compartment. If any
skipping of calibration points is observed, discontinue loading
until the problem is corrected. Please refer to the manuals for
these instruments for further details.
Installation
Installation of the system consists of connecting the appropriate
module into the gauge and programming alarm point 4. The
controller enclosure is mounted, connected via fiber optic cable
to the module, and wired to the rack sockets(s). Verification of
system operation completes the installation.