Connect the wiring to the pigtail

 

The following diagram shows the wiring from the sender to the display pigtail. Other wiring 
connections may apply for each display model.  All wiring diagrams are available on the website.

GROUND

TO 

+12V POWER

TO PUMP

INDICATOR

PIGTAIL

HARNESS

GALLEY

BLACK

GREY

FRESH STACKED

W

 

CAUTION: 

 It is very important that the display 

and senders have the same ground. Make sure the 
sender ground connection is connected back to the 
display ground or breaker panel ground.

W

 

CAUTION: 

 Wires are to be routed to the RIGHT 

side of the sender, away from the sender. Never 
route the wires to the left of the sender. If they 

drape over the sender they could affect the reading.

Example of stacked 
sender wiring

Summary of Contents for SeeLevel 710-JS

Page 1: ...from 5 to 7 5 high tanks and cannot be stacked The higher resolution is optimal for low profile tanks The 710 ES sender is 12 high not including tabs with a resolution of 3 8 and can measure tanks fr...

Page 2: ...ng senders The senders will need to have a flat area on the side of the tank large enough so the whole width of the sender is in contact with the side of the tank Make sure that any metal is at least...

Page 3: ...may sit more than 1 inch above the bottom of the tank Your water pump may begin to suck air before the tank is completely empty In these cases you want to install the fresh tank sender above the outl...

Page 4: ...on Manual 710 JS 710 ES 710 SS 710 JS Sender 2 6 SENDER SPECIFICATIONS 710 ES Sender 2 12 Blue signal wire Black ground wire Continuous pad Segmented pads 710 SS Sender 2 16 Segmented pads Segmented p...

Page 5: ...configuration whether they are on the top or bottom A pair of scissors or a hole punch can be used to cut the sender tabs The senders can be programmed for FRESH GREY BLACK and GALLEY tanks The tabs a...

Page 6: ...BOTTOM TOP TOP tab cut by mistake No Tabs cut W CAUTION TABS CUT IN ERROR If the GRY tab has been removed and it should be a black tank sender or if the BLK tab has been removed and it should be a gre...

Page 7: ...o cut for single senders GREY GRY BLACK BLK No Tabs cut GALLEY 4 Tank systems GRY ALT Examples for correcting cuts made in error FRESH GRY or BLK tab cut by mistake GRY BLK GRY BLK ALT PROGRAMMING THE...

Page 8: ...tape the sender to the tank wall Place a piece along the length of both sides of the sender and perform a test to verify operation W CAUTION Route wires to the right away from the senders The wires in...

Page 9: ...e GROUND TO 12V POWER TO PUMP INDICATOR PIGTAIL HARNESS GALLEY BLACK GREY FRESH STACKED W CAUTION It is very important that the display and senders have the same ground Make sure the sender ground con...

Page 10: ...on the display panel looks correct Signal strength test The signal power is an indication of how much signal is being transmitted through the tank wall and picked up by the receiver part of the sender...

Page 11: ...es Secure the wires with duct tape tie wraps or something similar so that the wires do not rattle or press against the sender this may result in sender damage or wires breaking over time Apply underco...

Page 12: ...Page 12 SeeLeveL Sender Installation Manual 710 JS 710 ES 710 SS INSTALLATION TIPS...

Reviews: