• Do not expose the device to excessive force, shocks, dust, temperature and humidity 
• Do not cover the ventilation holes with any objects like newspapers, curtains, etc. 
• Never immerse the device in water. If you spill liquid on it, dry it immediately with a soft, lint-free cloth 

• Do not clean the device with abrasive or corrosive substances 
• Do not handle the internal components of the device, as this will void your warranty  
• Use only fresh batteries. Never mix fresh and old batteries 
• Do not recharge the batteries. Place the station and its parts outside the reach of children 
• Do not throw old batteries to unsorted municipal waste, but use the designated areas 
• Dispose of this product in accordance with applicable regulations 
• Use only accessories specified by the manufacturer 
• Do not interfere with the internal circuits of the device, as this may void the warranty 
• The technical specifications are subject to change without notice

 

 

TECHNICAL PARAMETERS 

 

 

 

Main unit 

 

Power supply:  

 

 

 

 

 

AC adaptor 100-240 V, 50/60Hz, 0,3 A / 5V, 1,2 A 
2 pcs of 1.5 V AA batteries (mini) 

Temperature measurement range:   

 

 

-9,9°C to +50°C 

Accuracy of measurement:   

 

 

 

+/- 1°C 

Resolution: 

 

 

 

 

 

 

0.1°C 

Rel. humidity measurement range:   

 

 

20% to 95% 

Accuracy of measurement:   

 

 

 

+/- 5% 

Resolution: 

 

 

 

 

 

 

1% 

Absolute barometric pressure measurement range: 

600 hPa/mb to 1100 hPa/mb 

Dimensions:   

 

 

 

 

 

205 x 130 x 30 mm 

 

Wireless sensor GARNI 030H 

 

Power supply:  

 

 

 

 

 

2 pcs of 1.5 V AA batteries (mini) 

Outdoor temperature measurement range:   

 

-40°C to +70°C             

Accuracy of measurement:   

 

 

 

+/- 1°C 

Resolution: 

 

 

 

 

 

 

0.1°C 

Rel. humidity measurement range:   

 

 

20% to 95% 

Accuracy of measurement:   

 

 

 

+/- 5% 

Resolution: 

 

 

 

 

 

 

1% 

Data transmission frequency: 

 

 

 

433.92 MHz 

Number of channels:   

 

 

 

 

Maximum RF power:   

 

 

 

 

10 dBm (10 mW) 

Wireless sensor signal range: 

 

 

 

up to 60 m (in open space) 

Measurement interval: 

 

 

 

 

about 69 s 

Dimensions:   

 

 

 

 

 

49 x 95 x 32 mm 

 

 

GARNI technology a.s. hereby declares that the type of the radio equipment - weather station type GARNI 545 
Line conforms to the Directive 2014/53/EU. The full EU Declaration of Conformity is available on the following 
website: www.garni-meteo.cz 

 

 

The manual was prepared for GARNI technology a.s.                          by Roman Gajda.  
Reproduction of this manual or its parts is prohibited without the author's consent 

Version 03G20

 

Summary of Contents for 030H

Page 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Line Line ...

Page 2: ...wer limits of the outdoor temperature frost indication 5 icons of indoor thermal comfort weather forecast icons based on monitoring of changes in barometric pressure absolute barometric pressure display memory for maximum and minimum readings of temperature and rel humidity time and date controlled by DCF 77 radio signal with manual setting option 12 or 24 hour time display format alarm clock Moon...

Page 3: ...gs switching between displaying seconds and date 15 Button saving wake up time switching between displaying set wake up time and date 16 Button increase set value switching between display of the temperature readings in degrees Centigrade C or Fahrenheit F manual start stop of reception of the DCF 77 signal 17 Button decrease set value display of readings from individual wireless sensors manual st...

Page 4: ...remove them to avoid damage to the batteries and to the main unit Use only the delivered AC adaptor Powering with AC adaptor 1 Connect the AC adaptor plug into the socket on the rear side of the main unit 2 Connect the other side of the AC adaptor to a mains socket Battery power 1 Remove the battery compartment cover on the rear side of the main unit 2 Insert 2 pcs AA mini batteries observe the co...

Page 5: ...Placement near TVs monitors computers etc may negatively affect the reception of the DCF 77 signal and the wireless sensor signal Wireless sensor Place the wireless sensor away from direct sunlight not to compromise the measurement Placement outdoors at the northern wall is recommended Obstacles such as walls concrete metal structures and large objects reduce the signal range Position the wireless...

Page 6: ...ignal manually 3 Wait until the main unit automatically restarts the search 4 Set time and date manually Wireless sensor signal reception not successful 1 Check that the batteries in the wireless sensor are inserted correctly 2 Check that the wireless sensor is within the signal range 3 Press and hold button to start signal search manually Manual setting of time and date 1 Press and hold button un...

Page 7: ...PM 3 Current day of the week 4 Displaying the set wake up time pressing button or switches between displaying the day and month seconds and the set wake up time 5 Alarm clock on icon Indoor outdoor temperature and relative humidity Remote sensor the readings of the outdoor quantities from the wireless sensor sensors Indoor sensor the indoor readings measured by the main unit 1 Temperature unit C o...

Page 8: ...Barometric pressure decreased in the last 3 hours E g the weather forecast indicates rain the barometric pressure drops abruptly and quickly therefore the probability of heavy rain is higher Arrows of temperature relative humidity trends The main unit displays the trend icons of the measured quantities based on the temperature and relative humidity readings Temperature relative humidity increases ...

Page 9: ...perature pleasant Humidity pleasant Temperature higher or lower temperature than pleasant Humidity higher or lower humidity than pleasant Temperature unpleasant cold or hot Humidity unpleasant dry or wet Temperature too cold or hot Humidity too dry or wet CHANGING THE TEMPERATURE UNITS To change the temperature units to Centigrade C or Fahrenheit F press button DISPLAYING THE MAX AND MIN READINGS ...

Page 10: ...ton icon disappears Frost indication The frost indication function and the set point alarm are closely linked when the high and low temperature alarm is active the frost indication function is automatically activated As soon as the outdoor temperature is between 1 C and 3 C the icon is displayed Note Even if the icon is not displayed remember that there is a risk of icing at temperatures around ze...

Page 11: ...ote the main unit must be powered by the AC adaptor while charging the device TROUBLESHOOTING problem situation solution DCF 77 signal not received relocate the main unit start the manual signal search set the time and date manually instead of temperature and humidity readings temperature readings are outside the measurable range the display shows H HH or LL L the weather station is not working co...

Page 12: ...ptor 100 240 V 50 60Hz 0 3 A 5V 1 2 A 2 pcs of 1 5 V AA batteries mini Temperature measurement range 9 9 C to 50 C Accuracy of measurement 1 C Resolution 0 1 C Rel humidity measurement range 20 to 95 Accuracy of measurement 5 Resolution 1 Absolute barometric pressure measurement range 600 hPa mb to 1100 hPa mb Dimensions 205 x 130 x 30 mm Wireless sensor GARNI 030H Power supply 2 pcs of 1 5 V AA b...

Reviews: