Once the connection of the main unit to the wireless sensor is established, place the main unit  
and the wireless sensor in the desired location within the range of the wireless sensor signal 

 
Using multiple wireless sensors 

 

The main unit allows to connect up to 3 wireless sensors which can be placed at different spots. Each 
wireless sensor must be assigned its own channel number (1, 2 and 3).  

 

1) Place the main unit and the wireless sensor next to each other. 
2) Remove the battery compartment cover on the side of the wireless sensor. 
3) Assign a number to each wireless sensor using the switch so that the numbers are unique.  
4) Insert 2 pcs AA (mini) batteries, observe the correct polarity. Then push the TX button. A beep sounds 
    and the temperature readings from the wireless sensor are displayed on the main unit display. 
5) To display the readings from a given wireless sensor, select the desired channel on the main unit using 
    button 

 

To automatically change the channel in ascending order, press button 

 repeatedly until next to the 

channel number   a small arrow wheel   appears. The main unit will alternate between displaying the 
readings from all wireless sensors.  
 
The reception of the wireless sensor signal can be also started manually by pushing and holding button 

 

for 3 seconds. 
 

Placement of the weather station  

 

Main unit 

Select the location of the main unit away from direct sunlight. Test the connection to the wireless sensor 
before final installation. If there is a problem with the signal reception, select another location. There is a 
mounting hole for suspension on the rear of the main unit. You may also put the main unit on a flat surface 
using the folding support. Placement near TVs, monitors, computers, etc. may negatively affect the 
reception of the DCF-77 signal and the wireless sensor signal. 

 

Wireless sensor 

Place the wireless sensor away from direct sunlight not to compromise the measurement. Placement 
outdoors, at the northern wall is recommended. Obstacles such as walls, concrete, metal structures and 
large objects reduce the signal range. Position the wireless sensor vertically for optimum signal 
transmission. Maximum open space signal range is 60 meters. 
The signal range may be affected by obstacles (walls, trees) and other electrical devices (TVs, monitors, 
etc.). 

 

Time controlled by the DCF-77 radio signal 

 

The weather station is equipped with the DCF-77 time/date control signal receiver, the signal is 
broadcasted by a transmitter from Frankfurt am Main, Germany, with a range of about 1500 km. When 
outside this range, the time and date can be adjusted manually. The time and date are adjusted every day.  

 

When the batteries are inserted or the AC adaptor is plugged to the main unit, the display lights up, all 
display segments are briefly displayed, and a beep sounds and the wireless sensor signal reception 
commences.  
After the connection with the wireless sensor has been established, the reception of the DCF-77 is 

commenced, indicated by flashing icon 

. This process may take several minutes. The display will be off 

during the reception of the DCF-77 signal and the functionality of the main unit will be limited. Only buttons   

 and 

 will function. When the signal is received successfully, the display shows the current time, 

date and signal reception icon. The icon 

 shows the signal reception strength, the more bars the better 

the signal. The weather station will automatically receive the DCF-77 signal for time adjustment every day 
at 1:00, 2:00 and 3:00. If reception is unsuccessful, reception will be attempted again in another hour, five 

Summary of Contents for 030H

Page 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Line Line ...

Page 2: ...wer limits of the outdoor temperature frost indication 5 icons of indoor thermal comfort weather forecast icons based on monitoring of changes in barometric pressure absolute barometric pressure display memory for maximum and minimum readings of temperature and rel humidity time and date controlled by DCF 77 radio signal with manual setting option 12 or 24 hour time display format alarm clock Moon...

Page 3: ...gs switching between displaying seconds and date 15 Button saving wake up time switching between displaying set wake up time and date 16 Button increase set value switching between display of the temperature readings in degrees Centigrade C or Fahrenheit F manual start stop of reception of the DCF 77 signal 17 Button decrease set value display of readings from individual wireless sensors manual st...

Page 4: ...remove them to avoid damage to the batteries and to the main unit Use only the delivered AC adaptor Powering with AC adaptor 1 Connect the AC adaptor plug into the socket on the rear side of the main unit 2 Connect the other side of the AC adaptor to a mains socket Battery power 1 Remove the battery compartment cover on the rear side of the main unit 2 Insert 2 pcs AA mini batteries observe the co...

Page 5: ...Placement near TVs monitors computers etc may negatively affect the reception of the DCF 77 signal and the wireless sensor signal Wireless sensor Place the wireless sensor away from direct sunlight not to compromise the measurement Placement outdoors at the northern wall is recommended Obstacles such as walls concrete metal structures and large objects reduce the signal range Position the wireless...

Page 6: ...ignal manually 3 Wait until the main unit automatically restarts the search 4 Set time and date manually Wireless sensor signal reception not successful 1 Check that the batteries in the wireless sensor are inserted correctly 2 Check that the wireless sensor is within the signal range 3 Press and hold button to start signal search manually Manual setting of time and date 1 Press and hold button un...

Page 7: ...PM 3 Current day of the week 4 Displaying the set wake up time pressing button or switches between displaying the day and month seconds and the set wake up time 5 Alarm clock on icon Indoor outdoor temperature and relative humidity Remote sensor the readings of the outdoor quantities from the wireless sensor sensors Indoor sensor the indoor readings measured by the main unit 1 Temperature unit C o...

Page 8: ...Barometric pressure decreased in the last 3 hours E g the weather forecast indicates rain the barometric pressure drops abruptly and quickly therefore the probability of heavy rain is higher Arrows of temperature relative humidity trends The main unit displays the trend icons of the measured quantities based on the temperature and relative humidity readings Temperature relative humidity increases ...

Page 9: ...perature pleasant Humidity pleasant Temperature higher or lower temperature than pleasant Humidity higher or lower humidity than pleasant Temperature unpleasant cold or hot Humidity unpleasant dry or wet Temperature too cold or hot Humidity too dry or wet CHANGING THE TEMPERATURE UNITS To change the temperature units to Centigrade C or Fahrenheit F press button DISPLAYING THE MAX AND MIN READINGS ...

Page 10: ...ton icon disappears Frost indication The frost indication function and the set point alarm are closely linked when the high and low temperature alarm is active the frost indication function is automatically activated As soon as the outdoor temperature is between 1 C and 3 C the icon is displayed Note Even if the icon is not displayed remember that there is a risk of icing at temperatures around ze...

Page 11: ...ote the main unit must be powered by the AC adaptor while charging the device TROUBLESHOOTING problem situation solution DCF 77 signal not received relocate the main unit start the manual signal search set the time and date manually instead of temperature and humidity readings temperature readings are outside the measurable range the display shows H HH or LL L the weather station is not working co...

Page 12: ...ptor 100 240 V 50 60Hz 0 3 A 5V 1 2 A 2 pcs of 1 5 V AA batteries mini Temperature measurement range 9 9 C to 50 C Accuracy of measurement 1 C Resolution 0 1 C Rel humidity measurement range 20 to 95 Accuracy of measurement 5 Resolution 1 Absolute barometric pressure measurement range 600 hPa mb to 1100 hPa mb Dimensions 205 x 130 x 30 mm Wireless sensor GARNI 030H Power supply 2 pcs of 1 5 V AA b...

Reviews: