background image

 

 

SAFETY PRECAUTIONS

 

 

• Do not expose the device to excessive force, shocks, dust, temperature and humidity 
• Do not cover the ventilation holes with any objects like newspapers, curtains, etc. 
• Never immerse the device in water. If you spill liquid on it, dry it immediately with a soft, lint-free  
   cloth 
• Do not clean the device with abrasive or corrosive substances 
• Do not handle the internal components of the device, as this will void your warranty  
• Use only fresh batteries. Never mix fresh and old batteries 
• Do not recharge the batteries. Place the station and its parts outside the reach of children 
• Do not throw old batteries to unsorted municipal waste, but use the designated areas 
• Dispose of this product in accordance with applicable regulations 
• Use only accessories specified by the manufacturer 
• Do not interfere with the internal circuits of the device, as this may void the warranty 
• The technical specifications are subject to change without notice 

 

 

SPECIFICATION 

 

Main unit 

 

Power supply:  

 

 

power adaptor 230 V, 50 Hz, 90 mA / 4,5 V, 200 mA,   

 

 

 

 

 

3 pcs batteries type AAA 1.5 V (micro)  

Temperature measurement range:  -10°C to +50°C 
Accuracy of measurement:   

+/- 1°C 

Resolution: 

 

 

 

0.1°C 

Humidity measurement range: 

20% to 99% 

Accuracy of measurement:   

+/- 5% 

Resolution: 

 

 

 

1% 

Bar. pressure measurement range:  800 to 1100 hPa 
Dimensions:   

 

 

143 x 140 x 24 mm (without stand) 

 

 

Wireless sensor GARNI 045H 

 

Power supply:  

 

 

2 pcs AAA 1.5 V batteries type (micro) 

Temperature measurement range:  -40°C to +70°C 
Accuracy of measurement:   

+/- 1°C  

Resolution: 

 

 

 

0.1°C 

Humidity measurement range: 

20% to 99% 

Accuracy of measurement:   

+/- 5% 

Resolution: 

 

 

 

1% 

Transmission frequency: 

 

433 MHz 

Maximum RF output:   

 

10 dBm  (10 mW) 

Data transmission interval:   

50 s  

Range: 

 

 

 

up to 80 m in open space 

Dimensions:   

 

 

59 x 95 x 25 mm (without stand) 

 

 

GARNI technology a.s. hereby declares that the type of the radio equipment - weather station type GARNI 525  
conforms to the Directive 2014/53/EU. The full EU Declaration of Conformity is available on the following website: 
www.garni-meteo.cz 

 

 

 

 

The manual was prepared for GARNI technology a.s. by Roman Gajda.  
Reproduction of this manual or its parts is prohibited without the author's consent 
Version 1

 

Summary of Contents for 525

Page 1: ...1 INSTRUCTION MANUAL FOR WEATHER STATION MODEL GARNI 525 GARNI 525 ...

Page 2: ...pper and lower limits of the outdoor temperature time and date controlled by DCF 77 radio signal with manual setting option 12 or 24 hour time display format date alarm clock Moon phase 5 minute snooze function Snooze permanent display backlight option when on mains power 3 backlight brightness levels the main unit and the wireless sensor can be suspended or stand the wireless sensor is included i...

Page 3: ... 24 Wireless sensor low battery icon 25 Trend arrow 17 Date 18 Moon phase 19 Channel number 26 Indoor relative humidity 27 Main unit low battery icon 28 Indoor temperature 20 Icon of activated alarm clock Snooze function Zz 21 Time 29 Wireless sensor signal reception icon 30 Indoor relative humidity 22 DCF 77 signal reception icon Wireless sensor GARNI 045H ...

Page 4: ...all not be suspended but stand Wireless sensor 1 Remove the battery compartment cover on the rear side of the wireless sensor 2 Set the required channel using the CH switch 3 Insert 2 pcs AAA batteries micro observe the correct battery polarity 4 After the batteries are inserted a signal is sent to the main unit The signal can also be sent manually using the TEST button in the battery compartment ...

Page 5: ... of the main unit The main unit can be also placed on a flat surface using the two stands that are stored in the battery compartment and can be screwed into the two holes on the back of the main unit SETUP OF THE WEATHER STATION To enter the settings mode press and hold the SET button in the main screen mode for 3 seconds For settings use the MEM and CF buttons To save press the SET button once 1 ...

Page 6: ...date time are not adjusted then also at 2 03 3 03 4 03 and 5 03 Reception of the DCF 77 signal can be started manually by pressing and holding the CF button for 3 seconds Receiving and adjusting time can take up to 10 minutes The DST label next to the time indicates the daylight savings time MEMORY FOR MAX AND MIN MEASURED VALUES The main unit is equipped with memory for maximum and minimum measur...

Page 7: ...ay by briefly pressing the ALARM button The current time will reappear automatically after 20 s or after pressing of the SET button briefly Activating and deactivating the alarm clock Press the ALARM button briefly in the basic display mode to show the wake up time Press again to activate the alarm the icon will show together with the selected alarm mode MO SU or MO FR press again to deactivate th...

Page 8: ... s TROUBLESHOOTING problem possible cause solution time is not adjusted by the DCF 77 signal time is adjusted incorrectly incorrectly set timezone DCF 77 signal reception not on DCF 77 signal interference setting the correct timezone turning the DCF 77 signal reception on place the main unit away from other electrical equipment the outdoor temperature and rel humidity are not displayed the connect...

Page 9: ...Main unit Power supply power adaptor 230 V 50 Hz 90 mA 4 5 V 200 mA 3 pcs batteries type AAA 1 5 V micro Temperature measurement range 10 C to 50 C Accuracy of measurement 1 C Resolution 0 1 C Humidity measurement range 20 to 99 Accuracy of measurement 5 Resolution 1 Bar pressure measurement range 800 to 1100 hPa Dimensions 143 x 140 x 24 mm without stand Wireless sensor GARNI 045H Power supply 2 ...

Reviews: