background image

 

 

If the signal is not received, the DCF-77 signal reception icon will not appear on the display. If the signal is 

successfully received, the reception icon 

 will be permanently shown on the display. DST means 

daylight saving time. 
 
Search for the DCF-77 signal is done daily at 01:00, 02:00 and 03:00 a.m. If the signal is not successfully 
received at 03:00 a.m., the main unit will search for it at 04:00 and 05:00 a.m. Another search attempt 
occurs the next day at the same time. 
 
To start the search manually, press and hold the 

DOWN

 button for 3 seconds. To exit the search, briefly 

press the 

DOWN 

button. The other buttons are inoperative during the search, except the 

SNOOZE/LIGHT 

buttons. 

 

Note: the DCF-77 signal receiver for time and date setup is integrated into the main unit, therefore  
it is necessary to place the main unit in a way that guarantees good quality reception of the DCF-77 signal. 
Reception of the DCF-77 signal is indicated by the icon on the main unit display. 

 
 

THE WEATHER STATION SETUP 

 
To enter the setup mode, press and hold mode the 

MODE

 button down in the main screen for  

3 seconds. 
 

button 

setting 

steps 

press 

MODE 

for 3 

sec. 

entering the setup mode 

 

setting the time zone 

Press the

 UP 

or 

DOWN 

button to change the time 

zone (the setting for the Czech Republic and 
Slovakia is 00)

 

press 

MODE

 

setting the clock 

Press the 

UP

 button to increase value or 

DOWN

 

to reduce the set value 

press 

MODE

 

setting the minute 

Press the 

UP

 button to increase value or 

DOWN

 

to reduce the set value 

press 

MODE

 

setting the year 

Press the 

UP

 button to increase value or 

DOWN

 

to reduce the set value 

press 

MODE

 

setting the month 

Press the 

UP

 button to increase value or 

DOWN

 

to reduce the set value 

press 

MODE

 

setting the day 

Press the 

UP

 button to increase value or 

DOWN

 

to reduce the set value 

press 

MODE

 

language settings 

Press the 

UP

 or 

DOWN 

button to select the 

desired language 

press 

MODE

 

exit the setup mode 

 

 

Note: By holding down the UP or DOWN button when setting a given value, you will increase or decrease 
this value faster. 
If no button is pressed for 8 seconds, the last set value will be stored and the setting mode will end. 
Languages that can be set: ENG English, GER German, FRE French, ITA Italian, DUT Dutch, SPA Spanish, 
DAN Danish. 
 
Abbreviations of the day's name 
 
 

ENG 

GER 

FRE 

ITA 

DUT 

SPA 

DAN 

Monday 

MON 

MON 

LUN 

LUN 

MAA 

LUN 

MAN 

Tuesday 

TUE 

DIE 

MAR 

MSR 

DIN 

MAR 

TIR 

Wednesday  WED 

MIT 

MER 

MER 

WOE 

MIE 

ONS 

Thursday 

THU 

DON 

JEU 

GIO 

DON 

JUE 

TOR 

Friday 

FRI 

FRE 

VEN 

VEN 

VRI 

VIE 

FRE 

Saturday 

SAT 

SAM 

SAM 

SAD 

ZAT 

SAD 

LOR 

Sunday 

SUN 

SON 

DIM 

DOM 

ZON 

DOM 

SON 

 

Summary of Contents for 560 EASY II

Page 1: ...WEATHER STATION INSTRUCTION MANUAL MODEL GARNI 560 EASY II EASY II ...

Page 2: ...nd lower limits of indoor and outdoor temperature weather forecast icons based on barometric pressure changes time and date controlled by the DCF 77 radio signal with manual setting option 12 or 24 hour time display format date two alarm times snooze function can be set from 3 to 20 minutes USB port to charge mobile devices the possibility of constant display illumination the ability to hang or mo...

Page 3: ...tons wireless sensor 1 Mounting holes 2 Battery compartment 3 Folding stand 4 Power adapter socket 5 USB charging port 6 DOWN button 7 MODE button 8 SNOOZE LIGHT button 9 CHANNEL button 10 UP button 11 ALERTS button 12 ALARM button 13 No of selected channel outdoor temperature value battery icon 14 Relative outdoor humidity value signal icon DEVICE STARTUP Installing the batteries of the main unit...

Page 4: ...rged the icon will appear on the display of the wireless sensor and the icon on the main unit display in the outdoor section The connection must always be re established after replacing the batteries Placement Placement of the wireless sensor To avoid measurement distortion place the wireless sensor away from direct sunlight We recommend placement outside on the north wall Obstacles such as walls ...

Page 5: ...e time zone Press the UP or DOWN button to change the time zone the setting for the Czech Republic and Slovakia is 00 press MODE setting the clock Press the UP button to increase value or DOWN to reduce the set value press MODE setting the minute Press the UP button to increase value or DOWN to reduce the set value press MODE setting the year Press the UP button to increase value or DOWN to reduce...

Page 6: ... at 6 00 a m or alarm time 2 AL 2 default setting 0 00 a m Then press the MODE button again and hold for 3 seconds The hour digits begin to flash Use the UP or DOWN buttons to set the desired alarm hour and confirm by pressing MODE The minute digits begin to flash Use the UP or DOWN buttons to set the desired alarm minute Confirm the settings by pressing MODE If no button is pressed for 8 s during...

Page 7: ...ted on the display by the OFF symbol or the upper limit alarm HI or the lower limit LO when they are on Setting values for upper and lower temperature limits In the basic display press ALERTS and hold it for 3 s The upper limit of the outdoor temperature will flash Use the UP or DOWN buttons to set the desired value By pressing and holding these buttons the value will change more quickly To confir...

Page 8: ... can only charge your mobile device if the weather station is powered by an AC adapter Charging begins automatically when the mobile device is connected Watch the charging process and disconnect the cable from the USB port as soon as the mobile device is charged Note The USB port delivers a maximum charging current of 1000 mA WEATHER FORECAST The forecast is based on a change in barometric pressur...

Page 9: ...olution connection failure between the main shorten the distance between the main unit unit and the wireless sensor and the wireless sensor or change their placement metal structures frames etc place the main unit and the wireless sensor so as to between the main unit and the wireless sensor have as few obstacles as possible between them shorten the signal range the main unit or the wireless senso...

Page 10: ...r supply AC adapter 100 240 V 50 60 Hz 0 3 A 5 V 1 2 A 3 x AAA 1 5 V battery Temperature measurement range 0 C to 50 C Measuring accuracy 1 C Accuracy 0 1 C Humidity measurement range 20 to 95 Measuring accuracy 5 Accuracy 1 Dimensions 212 x 139 x 26 mm Wireless sensor GARNI 040H Power supply 2 x AAA 1 5 V batteries Temperature measurement range 30 C to 60 C Measuring accuracy 1 C from 0 C to 50 C...

Reviews: