18
MAGNASCANNER CS 5000
OWNER S MANUAL
' 2000 GARRETT METAL DETECTORS, INC.
4/30/00
PN 11674XX
Revised
8.5.
CONNECTORS
AC switches, DC switches and synchronization are connected through a screw terminal
block. Remote indicators and remote console are connected through RJ-45 telephone-
type connections.
8.6.
INDICATORS
READY
light indicates unit is operational;
ALARM
light and audible alarm are activat-
ed when target amount of metal is detected;
LED Bar Graph
indicates amplitude of
alarm signal.
8.7.
TRAFFIC COUNTER
Built-in and resettable with current reading easily available on LCD panel.
8.8.
TAMPERPROOF
Dual access codes required to set or change the operation of the unit: one level for use
by supervisors in selecting programs and sensitivity; the other for initial set-up and
overall control. Security of the unit s calibration settings is further protected by a non-
resettable sequence code that allows supervisors to maintain a precise log of all
changes ever made to the program, sensitivity or set-up, as well as any attempts at
changing them. An audible alarm reports any unauthorized attempt at access.
8.9.
CONSTRUCTION
Attractive scratch- and mar-resistant laminate with resilient end caps; control panel and
crosspieces of heavy duty aluminum.
8.10.
REGULATORY STANDARDS
Meets (or exceeds) all 1991 Federal Aviation Administration airport applications specifi-
cations as well as all requirements of National Institute of Law Enforcement and Crimi-
nal Justice (NILECJ) standard 0601.00, security levels 1-5.
8.11. REGULATORY INFORMATION
The Garrett Magnascanner CS 5000 meets or exceeds detection requirements of the
National Institute of Law Enforcement and Criminal Justice Standards #0601.00, levels
1-5, and Federal Aviation Administration airport application specifications. Programs
have been designed specifically to meet the three-gun test of the FAA and the require-
ments of the Undetectable Firearm Act of 1991.
The unit also complies with IEC standards for Safety Requirements for Electronic Mea-
suring Apparatus and meets the Federal Communications Commission Class B stan-
dards for noise emission from commercial electrical equipment. It also conforms to the
new European Electromagnetic Compatibility Directive, 89/336/EEC
-EN 55011, Group 2, Class B;-EN 50082-1