2.2.
TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions:
2.2.1.
STANDBY
When this touchpad is pressed, the unit goes into a low power mode, ready to be
returned to full operation when the
OPERATE
pad is touched. When
STANDBY
is dis-
played on the LCD, the green
READY
light is not visible and no processing can take
place in the unit. It is important to remember that the Power Switch located on the
Battery Back-up Module (See Page 42) should be set to its
OFF
position anytime the
system is being stored and anytime the system is not in use and is not connected to
AC power for more than 24 hours.
2.2.2.
OPERATE
Whenever this touchpad is pressed, the Magnascanner CS 5000 activates all circuits,
initiates a self-diagnosis program and places the unit in the Operate Mode within fifteen
(15) seconds. This diagnostic program for instant fault detection can be activated at any
time by touching this
OPERATE
pad. If any faults are ever found, they will be immedi-
ately reported on the LCD display. (See Page 10.)
2.2.3.
COUNTER
When this touchpad is pressed, the traffic count is displayed on the LCD display.
Pressing and holding this touchpad for ten (10) seconds causes the counter to return to
zero (0). Whenever the LCD is displaying information other than the current traffic
count, pressing this touchpad will cause the count to appear along with the Sequence
Number of changes that have been made to Program/Sensitivity settings.
CT (Number)
and
SEQ (Number)
will appear. Each time the Program/Sensitivity Mode is accessed,
the Sequence Code that appears on the LCD will be advanced one number. It is rec-
ommended that a written notation be made on the Operations Worksheet (see
Page 34) whenever this code is accessed, explaining reasons for the access. If the
ACCESS
touchpad has been pressed and an improper access code has been entered,
a * will appear before the sequence number (SEQ *37). This indicates that an unsuc-
cessful (unauthorized) attempt has been made to gain access to the
Program/Sensitivity setting.
MAGNASCANNER CS 5000
OWNER S MANUAL
' 2000 GARRETT METAL DETECTORS, INC.
4/30/00
PN 11674XX
Revised
4