background image

Magnum 10ETS / 10XTS Installation and User Guide 

06/12

 

 
 

46

www  GarrettCom  com

.

.

6.4 

Shipping and Packaging Information

 

 

Should you need to ship the unit back to GarrettCom, please follow these 

 instructions: 

 

1. 

 

Package the unit carefully.  It is recommended that you use the original 
container if available.  Units should be wrapped in a "bubble-wrap" plastic 
sheet or bag for shipping protection. (You may retain all connectors and this 
Installation Guide.) 

CAUTION

Do not pack the unit in Styrofoam "popcorn" type packing 

material.  This material may cause electro-static shock damage to the unit.

 

 

2.   Clearly mark the Return Material Authorization (RMA) number on the  

 

 

outside of the shipping container. 

 

3.    GarrettCom is not responsible for your return shipping charges. 

 

4.    Ship the package to: 

  

GarrettCom, 

Inc. 

 

 

47823 Westinghouse Dr.  

 

 

Fremont, CA  94539 

  Attn.:  Customer Service 

Summary of Contents for Magnum 10ETS

Page 1: ...www GarrettCom com Magnum 10ETS Ethernet Terminal Server Magnum 10XTS Router Terminal Server Hardware Installation and User Guide...

Page 2: ...zed personnel may render all warranties null and void If problems are experienced with a Magnum 10ETS or 10XTS product consult Section 6 Troubleshooting Copyright 2012 GarrettCom Inc All rights reserv...

Page 3: ...68 This device complies with part 68 of the FCC rules and the requirements adopted by the ACTA On the bottom of this equipment is a label that contains among other information a product identifier in...

Page 4: ...upply for DC units shall be Listed Direct Plug In power unit marked Class 2 or listed ITE Power Supply marked LPS which has suitably rated output voltage i e 24VDC or 48VDC and suitable rated output c...

Page 5: ...r 22 3 4 1 Power Input connection 22 3 5 Alarm Contacts for monitoring internal power and Software Traps 23 3 6 Connecting the Console Terminal 25 3 6 1 RJ45 Console port pin assignments 25 3 7 Module...

Page 6: ...DB9 DB 9 Serial module use in Slots C J 43 5 1 15 10TS4 RJ45 RJ45 Serial module use in Slots C J 43 5 1 16 10 2T1E1 Dual T1 E1 WAN adapter use in Slot I only 44 6 0 TROUBLESHOOTING 44 6 1 Before Call...

Page 7: ...le in modules at 2 per module or SFF Small Form Factor for high fiber port density 4 per module Each FDX or HDX default is FDX mode WAN Ports T1 E1 1 544 Mbps 2 048 Mbps G 703 Network Standards and Co...

Page 8: ...or detailed LED configurations One LED port indicating LINK solid green and ACTIVITY blinking Operating Environment Ambient Temperature 40 to 140 F 40 to 60 C for UL 60950 Component Parts rating 40 to...

Page 9: ...47 to 63 Hz auto ranging Management Console Connector RJ45 see details at Section 3 6 Mounting Rack mounting normal method Unit supplied with rack mounting brackets for mounting in a 19 rack Agency A...

Page 10: ...orts in a mix of Ethernet and Serial port combinations 10ETSR HSPHL Same as Model 10ETS HSPHL except chassis is a Reverse Mount unit All signal and power cables are in the rear 10ETS HSPLL Magnum 10ET...

Page 11: ...nal and power cables are in the rear 10ETS HL Same as Model 10ETS HH except the integral power supplies are one H 90 250V AC DC and one L 24 48VDC 10ETSR HL Same as Model 10ETS HL except chassis is a...

Page 12: ...of Ethernet and Serial port combinations 10XTSR HSPHL Same as Model 10XTS HSPHL except chassis is a Reverse Mount unit All signal and power cables are in the rear 10XTS HSPLL Magnum 10XTS Terminal Ser...

Page 13: ...al and power cables are in the rear 10XTS HL Same as Model 10XTS HH except the integral power supplies are one H 90 250V AC DC and one L 24 48VDC 10XTSR HL Same as Model 10XTS HL except chassis is a R...

Page 14: ...ver RJ45 auto negotiating Following IRIG B module can be configured in Slot B only IRIGB TMODULE Timing module for IRIG B w two BNC connectors Following modules can be configured in Slot C only Magnum...

Page 15: ...llowing module can be configured in Slot I only for the 10XTS Not available for the 10ETS Magnum 10XTS Slot I Port Module 10 2T1E1 Dual T1 E1 WAN adapter Slot locations Options Extras CONSOLE CBLQD Co...

Page 16: ...contain 1 Magnum 10ETS XTS Terminal Server base unit configured with user selected port module options installed and factory loaded MNS DX or MNS DX SECURE software installed 1 Set of two metal 19 rac...

Page 17: ...TS Router Terminal Server The Magnum 10XTS Router Terminal Server offers T1 E1 routing as well as advanced serial and Ethernet port configurability for heavy duty industrial applications where maximum...

Page 18: ...bled features NOTE Magnum 10ETS XTS will work with MNS DX Rel v3 1 6 firmware or higher version only Using any earlier MNS DX Rev level versions will not provide support for the Magnum 10ETS XTS Termi...

Page 19: ...fiber ports and support mixes of multimode singlemode 10Mb and 100Mb speed full and half duplex classic FX Small Form Factor SFF and Small Form Pluggable SFP connectors for fiber cable Relay Contacts...

Page 20: ...cations including redundant topologies MNS DX SECURE optional for extra security Magnum MNS DX SECURE software is designed for those customers demanding extra security in their networks MNS DX SECURE...

Page 21: ...d or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This section describes installation of the Magnum 10ETS XTS Ethernet Terminal Server as well as con...

Page 22: ...om com techsupport power_budget pdf for Power budget calculations to find fiber cable distance information 3 2 1 Connecting Shielded Twisted Pair CAT3 CAT5 The RJ45 ports of the Magnum 10ETS XTS can b...

Page 23: ...andwidth at longer distances about 70km with the singlemode LC 3 2 3 SFP Small Form factor Pluggable Transceivers The small form factor pluggable SFP is a compact fiber optic transceiver used in optic...

Page 24: ...evice 3 2 5 Connecting DB9 Serial ports This procedure assumes that one end of the serial device cable is already attached to the end unit Be aware of the serial port numbering scheme when installing...

Page 25: ...s should be in plain view and easy to read Rack mount installation requires special 19 rack mounted brackets and screws included with each Magnum 10ETS XTS unit These brackets attach to the each side...

Page 26: ...Magnum 10ETS 10XTS Installation and User Guide 06 12 20 www GarrettCom com Fig 3 3a 10ETS XTS front mount dimensions...

Page 27: ...Magnum 10ETS 10XTS Installation and User Guide 06 12 21 www GarrettCom com Fig 3 3b 10ETS XTS reverse mount dimensions...

Page 28: ...ble with 90 250V AC DC 24 48V DC and AC 100 240V via IEC connector power inputs When connecting the Ethernet or Serial cabling there is no need to power down the unit Individual cable segments can be...

Page 29: ...ly inside of the Magnum Switch The second NC Alarm Contact is a Software Alarm labeled S W operated by user settings in the MNS DX software The user can disable the Software Alarm feature with a softw...

Page 30: ...the Magnum 10ETS XTS unit and are green in color as shown in the picture Alarm contact ratings resistive 220 VDC 0 27A 60W 250VAC 0 25A 62 5VA 30VDC 2A 60W Fig 3 5a Alarm Contacts 1 2 hardware contro...

Page 31: ...or on the computer end Note For a detailed description of Managed Network Software MNS DX and Magnum 10ETS XTS Server software configuration for Network Management please refer to Magnum DX Software M...

Page 32: ...ry connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 3 7 Module...

Page 33: ...Data Out 4 IRIGb IRIG Clock signal Out 5 GND Signal Ground 6 IRIGb RTN IRIG Clock return Ground 7 RTS Request to Send Out 8 CTS Clear to Send In 9 NC Not Used DB9 Female Serial ports RS485 w IRIG B P...

Page 34: ...4 NC Not used 5 GND Signal Ground 6 NC Not used 7 CTS Clear to Send In 8 RTS Request to Send Out 9 NC Not used DB9 Female Serial ports RS232 DCE w IRIG B 10TS2 DB9 DCE IRIGB Pin Signal Description Dir...

Page 35: ...eive Data In 3 TXD Transmit Data Out 4 DTR Data Terminal Ready Out 5 GND Signal Ground 6 DSR Data Set Ready In 7 RTS Request to Send Out 8 CTS Clear to Send In 9 RI Ring Indicator In DB9 Female Serial...

Page 36: ...t Data Out 4 DTR Data Terminal Ready Out 5 GND Signal Ground 6 IRIGb IRIG Clock signal Out 7 RTS Request to Send Out 8 CTS Clear to Send In 9 IRIGb RTN IRIG Clock return Ground DB9 Female Serial ports...

Page 37: ...06 12 31 www GarrettCom com RJ48 T1 E1 Adapter ports Pin Signal Description Direction 1 RX Data Ring Receive In 2 RX Data Tip Receive In 3 NC Not used 4 TX Data Ring Transmit Out 5 TX Data Tip Transmi...

Page 38: ...rwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses are on the same port seg...

Page 39: ...it is desirable to operate the fiber link at 100Mb speed and at either half or full duplex mode depending on the capabilities of the remote device Standard commercially available Fast Ethernet media c...

Page 40: ...Magnum 10ETS XTS can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and internal switch buffers The Magnum 10ETS XTS switching hardware supports th...

Page 41: ...to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple...

Page 42: ...mode is 0 2 dB km ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 MAGNUM 10ETS XTS TERMINAL SERVER PORT MODULES This chapter describ...

Page 43: ...signations All ports have the following LED designations L A Link Activity Off No Link established ON Link established BLINKING Link Activity LED panel Power Indicator PS1 PS2 Illuminated when power i...

Page 44: ...emode 1550nm 40km fiber options as well as RJ45 copper see Sec 1 2 of this manual for available part numbers 5 1 4 IRIGB TMODULE two BNC connectors use in Slot B The IRIG B Timing module provides two...

Page 45: ...t software MNS DX or MNS DX SECURE the user may disable auto negotiation and fix the desired operation of each RJ45 port The user may select 10Mb or 100Mb speed and full or half duplex mode per port a...

Page 46: ...ing the advantage of future proof fiber optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has a Link...

Page 47: ...cannot be improperly inserted Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received 5 1 10 1...

Page 48: ...rovides four 100Mb open SFP ports supporting distances up to 40km This module provides the same functions as 10K4 MLC see Section 5 1 7 for more details SFP Transceivers are available with multimode 1...

Page 49: ...for time synchronization NOTE Module model IRIGB TMODULE is required in Slot B to enable the module to transmit the timing information 5 1 15 10TS4 RJ45 RJ45 Serial module use in Slots C J The 10TS4 R...

Page 50: ...contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable cha...

Page 51: ...Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma...

Page 52: ...in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This mat...

Page 53: ...minals are internally floating so that user may ground either PS1 Power Supply 1 Pin 1 Negative N Pin 2 Positive L Pin 3 Ground PS2 Power Supply 2 Pin 4 Ground Pin 5 Negative N Pin 6 Positive L Chassi...

Page 54: ...to suit the customer s use Before connecting live power lines to the terminal block always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is mor...

Page 55: ...ools Required 1 1 Phillips head screwdriver Step 1 Locate the Hot Swap power supply locking screw Loosen the locking screw until no longer engaged Step 2 Lift the Hot Swap power supply handle shown ab...

Reviews: