Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
35
www GarrettCom com
.
.
Note:
Do not use any other screws(except provided from the factor on the fan side.
Non-standard screws may stop the fan from working, and the heat build-up may
cause serious hazard to the unit.
3.10.2
Removing an SPM Bonus Port Module
To properly remove an SPM module from the Magnum 8000X Stackable
Concentrator follow the three steps below.
Step 1.
Remove chassis cover
See procedure in Section 3.10 above.
Caution: Be sure the power cord is unplugged.
Step 2.
Remove retaining screws for the SPM, face-plate only
On the rear side of the hub there are two retaining screws for the Bonus Port
slot. These are used to secure an SPM module in position. Remove them.
Step 3.
Remove SPM Card
Keep the face-plate screws available. Gently pull the SPM card up and out of
the connector header . If the bonus port from which the SPM card has been
removed is to remain unused, be sure to install an SPM face plate cover in it.
If another SPM card is replacing the one that has been removed, follow the
steps as described for installing an SPM card discussed in Section 3.10 on the
preceding pages.
3.11
Powering the Magnum 8000X
The Magnum 8000X incorporates an internal universal power supply, and has
a male IEC connector for the AC power cord at the right-rear. A six foot 115vac power
M AIN BOA RD
SPM
M OD ULE
POW ER
SU PPLY
STACKING
CONN ECTORS
Retaining
Screws
Fan