background image

Magnum P62-Series Hardened Switches                               Installation and User Guide (05/05)

 

 

 

21 

www  GarrettCom  com

.

.

 

3.0 INSTALLATION 

 

This chapter provides instructions for installing Magnum P62-Series units. 

 
3.1 

Locating Magnum P62F-Series 10/100Mb Ethernet Switches 

 

The location of a Magnum P62-Series Hardened Switch is dependent upon the physical 

layout of the network. The rugged 18-gauge sheet steel case that acts as a heat sink will normally 

protect the P62-Series from accidental damage in any application setting.  Install P62F models so 

that the metal case of the unit is in contact with a metal surface (such as a pedestal in the earth or 

an equipment enclosure box) which does not exceed the ambient rating of the unit.  Install mP62 

models mounted vertically, attached to any wood or metal surface or in free air. 

Designed primarily for specific applications such as roadside traffic data collection and 

control stations, unheated and or high temperatures locations, above-the-ceiling mounts in 

commercial buildings, industrial boiler rooms, mines and quarries, irrigation and pipeline 

facilities, on-board ships, cell towers, data communication huts and pedestals, aeronautical 

installations and military sites, the Magnum P62s support DC power input for high reliability and 

AC power for convenience in out-of-the way locations. Locate the P62-Series unit near any AC 

power (or any 20-60VDC three-wire (+, GND, -) power source for DC models) that is within the 

range of the unit. When installing the unit, be sure to maintain an open view of the top surface to 

visually monitor the status LEDs. 

 
3.1.1 

Mounting position and materials 

 

The Magnum P62-Series Hardened Switch should be securely mounted in a vertical 

position with appropriate screws.  Rubber “feet” (if any) that would insulate the case from metal-

to-metal contact with the mounting surface should be removed. The full temperature rating of the 

P62F unit cannot be achieved if it is not properly mounted on metal.   

The Magnum P62-Series Hardened switches are quite heavy (3.5 lbs, 1.6 Kg)  because 

of its 18-gauge high-strength steel case enclosure. Because of its weight, it is very important to 

select a sturdy place and carefully attach it to metal surface. Attaching P62F’s to a metal surface 

is necessary to allow the thermal heat transfer from the case, achieving rated ambient temperature 

specifications. The mP62’s can be mounted on any material. 

 
3.1.2 Mounting 

dimensions 

Each Magnum P62-Series Hardened Switch is normally  mounted with screws in a 

vertical (cables at the bottom) position. The base plate of the unit has screw holes cut out, two top 

and two bottom. The spacing for the mounting screws is a rectangle 3.35” x 7.92” (8.5cm x 

Summary of Contents for Magnum mP62-5V -1M1SSC

Page 1: ...5 00 USD www GarrettCom com Magnum P62 Series P62F and managed mP62 models Hardened Ethernet Switches Installation and User Guide...

Page 2: ...Manager patent pending and Link Loss Learn patent pending are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum P62 Series Hardened Ethernet Switches contain...

Page 3: ...adiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and fo...

Page 4: ...100 and 2 100Mb fiber ports managed and unmanaged models all fiber types Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing AC and DC power Dual Speed 8 port and 16 port Stackables 10 100 au...

Page 5: ...wist Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shield 23 3 2 2 Connecting Fiber Optic SC type Snap In 24 3 2 3 Connecting Fiber Optic ST type Snap In Optional 24 3 2 4 Connecting Single Mode Fiber Optic...

Page 6: ...70VDC to 20 60VDC Rev G 03 03 This revision adds the DIN RAIL mounting options UL requirement for DC Rev F 11 02 This revision adds the Managed mP62 models Rev E 06 02 Changed Altitude spec and added...

Page 7: ...880 pps max Processing type Store and Forward Auto learning 4K address table 16K on P62F shared for all ports Packet buffers 256KB dynamically shared on all domains Latency not including packet time 1...

Page 8: ...and 10 100 speed each inde pendently auto negotiating on P62F models S W controlled on mP62 models Fiber Ports 1 and 8 The switched fiber ports 1 8 are fixed at full duplex only 100Mb speed Mechanica...

Page 9: ...ales GarrettCom com for details Agency Approvals UL Listed UL 60950 cUL CB CE Low Volt Dir Electro Magnetic Comp IEEE P1613 Class 2 Environmental Standard for Electric Power Subs See also Note for Pow...

Page 10: ...that filters and forwards data moving between the ports The internal switch has 16K nodes address table and 1MB packet buffers DC power input 20 60VDC auto ranging Steel case acts as a heat sink Rated...

Page 11: ...e ports Software and buffers same as mP62 AC 2MSC Dc power input 20 60VDC auto ranging Magnum mP62 1MISSC Same as mP62 2MSC except one fiber port is 20km single mode SC No PSX unit required Magnum mP6...

Page 12: ...tion and User Guide 1 Product Registration Card Optional if AC power 1 PSX A Power Source Extended Temp unit 1 6 ft long AC Power chord for PSX A Unit only Optional PSX T 125 or 250VDC 1 PSX T Power S...

Page 13: ...provide the switching speed and the reliability to smoothly support multiple workgroups at 100Mbps or 10Mbps speed The optional fiber ports are normally configured and tested with Magnum P62 units in...

Page 14: ...her bandwidth and longer distances on fiber All the LEDs are mounted on the top cover to conveniently indicate operating status of all ports There is a power on PWR indicator and a SELF TEST self test...

Page 15: ...Magnum mP62 5V mP62 5V with the PSX A AC model The Managed mP62 model is equipped with industry standard network management and utility software operating features to make this Switch suitable to dep...

Page 16: ...max of 75 C which is 5 C more than the P62F product ratings of 70 C Equipped with high thermal dissipation features patent pending power supply flexibility management MNS mP software capability and a...

Page 17: ...mail support GarrettCom com for further information 2 2 4 Connecting the Console Terminal to Magnum mP62 Management Use a DB 9 null modem cable to connect the Magnum mP62 Console Port the RS 232 port...

Page 18: ...and can be order from the factory along with the unit NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console port...

Page 19: ...and forward switch Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the...

Page 20: ...ces to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a sma...

Page 21: ...ng in any situation As the units are normally vertical for wall or pedestal mounting top surface viewing is most convenient Installation is Plug n Play operation is transparent to software The Magnum...

Page 22: ...witch serves this requirement economically and efficiently The six full and half duplex switched ports make the required setup simple for collection of traffic data The uncontrolled outdoor temperatur...

Page 23: ...ide an exceptional Ethernet product Figure 2 6 2 Three P62F connects together to provide 10 Mbps and100Mbps network with Fast Ethernet backbone In this example the extended temperature rated P62F take...

Page 24: ...features provide a very economical and efficient solution to this requirement The advanced Link Loss Learn feature will provide a very secure and effective solution in this particular kind of environm...

Page 25: ...for high reliability and AC power for convenience in out of the way locations Locate the P62 Series unit near any AC power or any 20 60VDC three wire GND power source for DC models that is within the...

Page 26: ...es measurement information for the PSX unit mounted on top if present and for the Magnum P62 Series unit 3 35 8 5 1 44 3 7 1 64 4 2 2 20 60 VDC TX 0 7A MAX RX 1F POWER SELF TEST LK ACT 10 100 www Garr...

Page 27: ...le mode 9 125 microns cabling should be used Fiber cabling supports much longer cable distances and higher bandwidth than copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T R...

Page 28: ...pe Snap In The following procedure applies to installations using SC type fiber connectors This procedure applies to ports using multi mode SC fiber connectors 1 Before connecting the fiber optic cabl...

Page 29: ...the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power...

Page 30: ...eady ON It is OFF if there is no traffic or if 10 Mbps traffic 3 3 Powering the Magnum P62 Series Hardened Switch 3 3 1 Power P62F and mP62 models for 48V and 24V DC pwr input Each Magnum Model P62 Se...

Page 31: ...rement use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block 3 3 2 Power the P62 5V models w Ext AC Powe...

Page 32: ...nded temperatures to be accommodated The PSX T also includes reverse polarity protection to prevent damage in case the unit is accidentally hooked up backwards The DC power output cord comes with a mi...

Page 33: ...nection to earthing wiring 8 Use only with Listed 10 A circuit breaker provided in building installation 9 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 10 Fasten...

Page 34: ...on a DIN RAIL track order the optional bracket Model DIN RAIL P62 and use the DIN Rail mounting bracket procedure as illustrated in the picture below See also the GarrettCom web site at http garrettc...

Page 35: ...plex and auto sensing for speed See section 2 2 When the connected device is 10 Mbps P62s obey all the rules of 10 Mbps Ethernet configurations The 10 Mbps users share a 10 Mbps traffic domain and can...

Page 36: ...rks They are self learning so that as nodes are added or removed or moved from one segment to another the P62 Series automatically keeps up with node locations An address aging algorithm causes least...

Page 37: ...media converters etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software and the result of the auto negotiation is changed in t...

Page 38: ...tion Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have be...

Page 39: ...personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence...

Page 40: ...t in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping...