32. USER PARAMETER & TECHNICIAN PARAMETER:
Parameter
Parameter Function
Range
Default
Key
Description
In the normal screen, press [P]
P01
Maximum Sewing Speed (r/S) 100-3700
3700
+/-
Maximum speed of machine sewing
P02
Speed Curve Adjustment (%]
1-100
80
+/-
The Lager the value, the faster to
increase speed
P03
Needle UP/DOWN
UP/DN
DN
+/-
UP: Needle Stops at Up Position
DN: Needle Stops at Down Position
P04
Start Back-Tacking Speed
(r/S)
200-3200
1800
+/-
Start Back-Tacking Speed Adjustment
P05
End Back-Tacking Speed (r/S)
200-3200
1800
+/-
End Back-Tacking Speed Adjustment
P06
Bar-Tacking Speed (r/S)
200-3200
1800
+/-
Repeat Bar-Tacking Speed Adjustment
P07
Soft Start Speed (r/S)
200-1500
400
+/-
Soft Start Speed Adjustment
P08
Stitch Numbers for Soft Start
0-99
2
+/-
Soft Start Stitches Setting (one unit =
half stitch)
P09
Automatic Constant-Stitch
Sewing Speed (r/S)
200-4000
3700
+/-
Constant Stitch sewing speed
[034.SMP] is set at A (or when one
shot signal is active)
P10
Automatic End Back-Tacking
Sewing (Can invalidate the
stitch correction function)
ON/OFF
ON
+/-
The Stitch-Correction is valid in
sewing stop.
Note: Valid only when the [0.11.RVM]
must set on B
ON: Invalid (Constant-Stitch sewing, it
can automatic continue action as CD
function)
OFF: Valid (Can´t continue execute CD
function)
P11
Back-Tacking Mode Selection
J/B
J
+/-
J: JUKI Mode (it will active when
machine is stopped or running
B: BROTHER Mode (it will active only
the machine is running)
P12
Start Back-Tacking Mode
Selection
A/M
A
+/-
A: One shot to pedal, it will automatic
execute Start Back-Tacking.
M: Pedal-controlled and motor can
stop arbitrarily.
P13
Mode Selection at the end
Back-Tacking
CON/STP
CON
+/-
CON: At the end of Start Back-
Tacking, machine continues sewing if
pedal pressed or START signal on
(standing operation)
STP: At the end of Start Back-Tacking,
machine stop
P14
Soft Start
ON/OFF
ON
+/-
ON: Slow start feature is turned on
OFF: Slow start function off
P18
Stitch Balance for Start Back-
Tacking 1
0-200
0-200
131
+/-
0
200 Action gradually lag
P19
Stitch Balance for Start Back-
Tacking 2
158
+/-
P20
Mode Selection for End Back-
Tacking
A/M
A
+/-
A: Pedal full heeling, it will automatic
execute end Back-Tacking
M: Pedal-controlled and motor can
stop arbitrarily
P21
End Back-Tacking Function
Selection
ON/OFF
ON
+/-
ON: Termination feature is turned
back seam
OFF: End back seam is off
Quick Setup from the front, where
the setting is valid
www.garudan.cz
Summary of Contents for GF-3131-447 MH
Page 31: ...MP03100EN_180625 A ARM MECHANISM 1 2 ANITA 2 ANITA 4 w w w g a r u d a n c z...
Page 33: ...MP03100EN_180625 A ARM MECHANISM 2 2 ANITA 2 ANITA 6 w w w g a r u d a n c z...
Page 43: ...MP03100EN_180625 D FEED MECHANISM 1 2 ANITA 1 2 ANITA 16 w w w g a r u d a n c z...
Page 45: ...MP03100EN_180625 D FEED MECHANISM 2 2 ANITA 2 2 ANITA 18 w w w g a r u d a n c z...
Page 47: ...MP03100EN_180625 E PRESSER FOOT MECHANISM ANITA ECHANISM ANITA 20 w w w g a r u d a n c z...
Page 49: ...MP03100EN_180625 F ROTARY HOOK MECHANISM ANITA ECHANISM ANITA 22 w w w g a r u d a n c z...
Page 55: ...MP03100EN_180625 H LUBRICATION ANITA ANITA 28 w w w g a r u d a n c z...
Page 57: ...MP03100EN_180625 I REVERSE FEED COMPONENTS ANITA OMPONENTS ANITA 30 w w w g a r u d a n c z...
Page 59: ...MP03100EN_180625 J INBUILT FOOT LIFT STRUCTURE ANITA RUCTURE ANITA 32 w w w g a r u d a n c z...
Page 63: ...MP03100EN_180625 L ACCESSORIES ANITA ANITA 36 w w w g a r u d a n c z...