Parameter
Parameter Function
Range Default Key
Description
Please contact the ANITA B Service Center to enter service settings
P44
Brake force
0-31
16
+/- Efforts to stop the machine when selecting
P45
Back-seam operation duty
cycle (%)
10-90
30
+/- Back-seam action to periodic power output
P46
Motor stops with a reverse
angle after trimming
ON/OFF
OFF
+/-
ON: It will automatic as reverse function
after trimming (angle adjustment according
to the parameter [047.TR8]
OFF: No Function
P47
Adjustment of reverse angle
after trimming
50-200
160
+/- Adjusting at reverse direction after trimming
P48
Low (Positioning) Speed (r/S) 100-500
210
+/- Setting Positioning Speed
P49
Trimming Speed (r/S)
100-500
250
+/- Adjusting trimming speed
P50
The time of Foot lifting
10-990
250
+/- Adjustment of foot lifting action
P51
Duty-Cycle Setting for Foot
Lifter (%)
10-90
30
+/-
Adjustment for Duty-Cycle of Foot Lifter /
Back-Tacking (Fine tuning can reduce the
over heating)
P52
The time of Foot down
10-990
120
+/- Adjustment of foot down action
P53
Cancel foot Lifting when Half-
Heeling the Pedal
ON/OFF
OFF
+/-
ON: Pedal half heeling without foot lifting
function
OFF: Pedal half heeling with foot lifting
function
P54
Trimming Time (ms)
10-990
200
+/- Trimming sequence time setting
P55
Setting Wiper Timing
10-990
380
+/- Wiper sequence setting
P56
Needles Goes Up
Automatically as Power
turned on
ON/OFF
ON
+/-
ON: Power turned on, needle goes up
position automatically
OFF: No Function
P57
Protection time for lift lifter
(S)
1-120
10
+/-
It will automatic come down when foot lifter
keep lift over the setting time
P58
Up Position Adjustment
0-1439
40
+/-
UP Position Adjustment
The needle will advance stop when the value
decreased
The needle will delay stop when the value
increased
P59
Down Position Adjustment
0-1439
750
+/-
Down Position Adjustment
The needle will advance stop when the value
decreased
The Needle will delay stop when the value
increased
P60
Testing Speed (r/S)
100-
3700
2000
+/- Setting testing Speed
P61
Testing A
OFF
+/-
Option of Testing A, after setting press
[060.TV] to set the speed keep running.
P62
Testing B
OFF
+/-
Option of Testing B, after setting press
[060.TV] to set the speed execute the cycle
of Start-Sewing-Stop-Trimming
P63
Testing C
OFF
+/-
Option of Testing C, after setting press
[060.TV] to set the speed execute the cycle
of Start-Sewing-Stop without positioning
function
P64
Running Time of Testing B
and C
1-250
20
+/- Setting running time of testing B and C
P65
Stop Time of Testing B and C
1-250
20
+/- Setting stop time of testing B and C
www.garudan.cz
Summary of Contents for GF-3131-447 MH
Page 31: ...MP03100EN_180625 A ARM MECHANISM 1 2 ANITA 2 ANITA 4 w w w g a r u d a n c z...
Page 33: ...MP03100EN_180625 A ARM MECHANISM 2 2 ANITA 2 ANITA 6 w w w g a r u d a n c z...
Page 43: ...MP03100EN_180625 D FEED MECHANISM 1 2 ANITA 1 2 ANITA 16 w w w g a r u d a n c z...
Page 45: ...MP03100EN_180625 D FEED MECHANISM 2 2 ANITA 2 2 ANITA 18 w w w g a r u d a n c z...
Page 47: ...MP03100EN_180625 E PRESSER FOOT MECHANISM ANITA ECHANISM ANITA 20 w w w g a r u d a n c z...
Page 49: ...MP03100EN_180625 F ROTARY HOOK MECHANISM ANITA ECHANISM ANITA 22 w w w g a r u d a n c z...
Page 55: ...MP03100EN_180625 H LUBRICATION ANITA ANITA 28 w w w g a r u d a n c z...
Page 57: ...MP03100EN_180625 I REVERSE FEED COMPONENTS ANITA OMPONENTS ANITA 30 w w w g a r u d a n c z...
Page 59: ...MP03100EN_180625 J INBUILT FOOT LIFT STRUCTURE ANITA RUCTURE ANITA 32 w w w g a r u d a n c z...
Page 63: ...MP03100EN_180625 L ACCESSORIES ANITA ANITA 36 w w w g a r u d a n c z...