34. PORT OUTLINE DIAGRAM:
The name of each port
14P function port table:
- trimming solenoid: 1, 8
- clamp, dial line solenoid: 2, 9
- clothing lights: 4 (signal ground), 11 (+5v)
- backstitch manually switch: 5 (sensor signal), 12 (signal ground)
- backstitch solenoid: 6, 13
- complement Needle switch: 7 (sensor signal), 14 (signal ground)