ANITA ©
MP00006EN_181206
49
23 Trim delay (ms)
52 to 1020
Trim delay (default value is 52)
24 Blocking after trim (ms)
0 to 1024
Time of blocking the motor of needle after sewing/trimming (default value is
100)
25 Reverse angle (°)
0 to 90
Reverse angle of the motor of needle after sewing/trimming (default value is
0)
26 Up stop position (°)
-180 to 180
Up stop position angle (default value is -35)
27 Trim time limit (10ms)
Protection of trimming
100 to 1600
This function is for protection of trimming solenoids. When the time for
closing of solenoid is longer, machine reports an error message (default value
is 200)
28 Wiper time limit (10ms)
Protection of wiper
100 to 1600
This function is for protection of wiper solenoids. When the time for closing of
solenoid is longer, machine reports an error message (default value is 200)
29 Jump speed (1/min)
10 to 400
Speed of movement in JUMP parts of the pattern. (default 100)
www.garudan.cz
Summary of Contents for GPS/G-10060
Page 69: ......