List of parameters for exchange of needles:
PN01 Needle changer
0 Disable
Machine is not equipped with device for exchange of needles. (default)
1 Enable
Machine is equipped with device for exchange of needles – change of
thread color in sewing is possible.
PN02 Clutch switch off time (ms)
10 to 10000
Period of delay of clutch switch release. (default value is 10)
PN03 Needle change time (ms)
10 to 10000
Period necessary for switching of needle from one to the other position.
For switching from first needle to second or vice versa the same value is
used (default value is 80)
PN04 Second wiper
0 Disable
Machine is not equipped with second wiper/thread holder (default)
1 Enable
Machine is equipped with second wiper/thread holder
PN05 Wiper 1 release (ms)
50 to 500
Time delay, when thread 1 is held by wiper after start of sewing process.
(default value is 100)
PN06 Wiper 2 release (ms)
50 to 500
Time delay, when thread 2 is held by wiper after start of sewing process.
(default value is 100)