ANITA ©
MP00006EN_181206
57
12.3
List of parameters for pocket device:
PA06 Feed plate up time (ms)
50 to 500
Time delay necessary for movement feed plates to upper position.
PA07 Size change time (ms)
50 to 500
Time delay necessary for change size of inner feed plate.
PA09 FF fast size change
0 Disable
Inner feed plate change size only after trim, when sewing is finished.
1 Enable
Inner feed plate change size immediately after command. Inner feed plate
can change size in sewing process. It is not necessary do thread trim for
change size of inner feed plate.
www.garudan.cz
Summary of Contents for GPS/G-10060
Page 69: ......