05 Operation of feed plate
0 Disable
The frame is permanent in lower position. It is not possible to control the feed
plate.
1 Auto open
After sewing and positioning the feed plate is automatically lifted (default)
2 Hold
After sewing and positioning the feed plate is in lower position but you can
control it by pedals.
3 Open before
After sewing feed plate is lifted and goes to start position.
4 Sew down
The frame is permanent in lower position. It is not possible to control the feed
plate.
06 Feed plate type
0 Simple feed plate
One feed plate (default setting for model GPS/G-3020)
1 Two feed plates
Two feed plates – left and right (default setting for models GPS/G-1507,
GPS/G-2010, GPS/H-1510 and GPS/H-2010)
2 Upper and bottom Two feed plates – upper and bottom (default setting for model – GPS/G-
3525, GPS/G-4032, GPS/G-6032, GPS/G-6040 and GPS/G-10060)
3 Label device
Machine has device for sewing labels (optional device).
4 Holding jump
Machine has two holders for fixation material in jump moving.
5 Pocket device
Machine with device with two sizes of pocket holder. Timing is by parameters
PA06, PA07 a PA09.
07 Feed plate Check
0 Disable
The control position of the feed plate is disabled.
1 Enable
The control position of feed plate is enabled. Before sewing the system of
machine checks if frames are in bottom position. If feed plate is not in
bottom position, the sewing is not possible (default).
2 Active
Before sewing the system of machine checks if frames are in bottom position.
If feed plate is not in bottom position, feed plate is lowered by machine.
08 Signal of pedal 1 (left)
0 Disable
No function for left pedal.
1 Start sewing
By pressing the pedal machine is sewing (default)
2 Left feed plate
By pressing the pedal you can take control of left or upper feed plate.
3 Right feed plate
By pressing the pedal you can take control of right or bottom feed plate.
4 Both feed plates
By pressing the pedal you can take control of both feed plates.
5 Label device
Label device is commanded by pedal (it is necessary to set parameter
06 Feed
plate type
to value
3 Label holder
).