CAN/RS-485 Interface (X39)
6.4
Pin Name
Description
Level
1
GND_CAN_RS485
Ground for CAN and RS485 group
2
CAN1_TERM
To enable CAN1-Termination, bridge
with CAN1_H
3
CAN1_H
CAN bus 1 high
-
24…+24 V
4
CAN1_L
CAN bus 1 low
-
24…+24 V
5
CAN1_TERM
To enable CAN1-Termination, bridge
with CAN1_L
6
RS485_TERM
To enable RS485-Termination: bridge
with RS485_A
7
GND_CAN_RS485
Ground for CAN and RS485 group
8
n.a.
9
RS485_Y
TX+
-
7…+12 V
10
RS485_Z
TX-
-
7…+12 V
11
RS485_A
RX+, to enable Half-Duplex: bridge with
RS485_Y
12
RS485_B
RX- , to enable Half-Duplex: bridge with
RS485_Z
Header: Molex 43045-1200 Micro-Fit 12p
Plug: Molex 43025-1200 Micro-Fit 12p, crimp contact Molex 43030-0007
Shielding with 6,3 mm male spade terminal connector
CAN/RS-485 (X14) is not galvanic isolated from System-GND/Housing
CAN1/CAN2 *
Pin Name
Description
Level
1-5
Identical to standard
6
n.a.
7
GND_CAN_RS485
Ground for CAN group
8
CAN2_TERM
To enable CAN2-Termination, bridge
with CAN2_H
9
CAN2_H
CAN bus 2 high
-
24…+24 V
10
CAN2_L
CAN bus 2 low
-2
4…+24 V
11
CAN2_TERM
To enable CAN2-Termination, bridge
with CAN2_L
12
n.a.
Summary of Contents for VINCELL 7.0
Page 1: ...VINCELL 7 0 Senso Glass IPS Manual For PCB revision 0 7 or for HW 1 1 or later...
Page 21: ...VINCELL 7 0 Senso Glass IPS Manual 21 Battery 6 10 Battery VINCELL V1 1 1...
Page 28: ...VINCELL 7 0 Senso Glass IPS Manual 28 Annex D Quality and Incoming Inspections D 1 Display...
Page 29: ...VINCELL 7 0 Senso Glass IPS Manual 29...
Page 30: ...VINCELL 7 0 Senso Glass IPS Manual 30...
Page 31: ...VINCELL 7 0 Senso Glass IPS Manual 31 D 2 Touch...
Page 32: ...VINCELL 7 0 Senso Glass IPS Manual 32...
Page 33: ...VINCELL 7 0 Senso Glass IPS Manual 33...
Page 34: ...VINCELL 7 0 Senso Glass IPS Manual 34 D 3 Evaluation criteria of standard display module...