Safety Hints

Please read this section carefully and observe the instructions for your own safety and correct use of the device. 
Observe the warnings and instructions on the device and in the manual. Garz & Fricke embedded systems have 
been built and tested by us and left the company in a perfectly safe condition.In order to maintain this condition 
and ensure safe operation, the user must observe the instructions and warnings contained in this manual.

I.  General Handling

  Don’t drop or strike the unit: The PCB, display and/or other parts might be damaged.

  Keep away from water and other liquids, the unit is not protected against.

  Operate the unit under electrical and environmental conditions according to the technical 

specification.

  The electrical installations in the room must correspond to the requirements of the local 

(country-specific) regulations.

  Take care that there are no cables, particularly power cables, in areas where persons can trip 

over them.

  Do not place the device in direct sunlight, near heat sources or in a damp place.

  All plugs on the connection cables must be screwed or locked to the housing.

  Repairs may only be carried out by qualified specialist personnel authorized by 

Garz & Fricke GmbH or their local distributors.

  Maintenance or repair on the open device may only be carried out by qualified personnel 

authorized by Garz & Fricke GmbH which is aware of with the associated dangers.

II.  Electricity

  The embedded systems may only be opened in accordance with the description in this user’s 

manual for 

- replacing of the (rechargeable, where applicable) lithium battery and/or 

- configuration of interfaces, where applicable

  These procedures have to be carried-out only by qualified specialist personnel.

  When accessing internal components the device must be switched off and disconnected from 

the power source.

  When purchased core or basic versions without protecting back cover, don’t touch the PCB 

directly with your fingers. Especially these products need to be handled very carefully.

  Don’t operate or handle the unit without typical ESD protection measures, such as ground 

earthing.

  Operate the unit according to the technical specification only.

III.  Damage or Permanent Malfunction

  It must be assumed that a safe operation is no longer possible, in case 

-the device has visible damage or 

-the display is dark or shows strange pattern for longer period 

-the device doesn’t react after a reset

  In these cases the device must be shut down and secured against further use

Summary of Contents for SANVITO 10.1 WM V2.1

Page 1: ...WE MAKE IT YOURS SANVITO 10 1 WM V2 1 ARM Cortex A9 Product Manual ...

Page 2: ...ion V2 1 2 PRODUCT MANUAL SANVITO Document Revision History The information in this document is subject to change without prior notice in order to improve reliability design and function and does not represent a commitment on the part of the manufacturer Online support on www garz fricke com ...

Page 3: ...r 14 5 8 Expansion Board Connector PCIe 15 5 9 Figure Mainboard 16 6 Wall Installation Instructions 17 6 1 On Wall Cable Mounting with Cable Inlet 17 6 2 Wall Installation 18 Annex A Technical Drawing 20 Annex B Quality and Incoming Inspections 21 B 1 Display and Touch 21 Annex C Hardware Revision Information 22 Annex D Guidelines and Standards 23 D 1 RoHS Declaration 23 D 2 Supplier Declaration D...

Page 4: ...s it can be proven that we are aware of such errors or inaccuracies or that we are unaware of these as a result of gross negligence and Garz Fricke has failed to eliminate these errors or inaccuracies for this reason Garz Fricke GmbH expressly informs that this manual only contains a general description of technical processes and instructions which may not be applicable in every individual case In...

Page 5: ...only be carried out by qualified specialist personnel authorized by Garz Fricke GmbH or their local distributors Maintenance or repair on the open device may only be carried out by qualified personnel authorized by Garz Fricke GmbH which is aware of with the associated dangers II Electricity The embedded systems may only be opened in accordance with the description in this user s manual for replac...

Page 6: ...Hamburg Made in Germany PRODUCT MANUAL SANVITO 3 Product Introduction The SANVITO 10 1 WM V2 1 is a control and operating unit for various applications 3 1 Serial number For service and later identification of the device a label containing the serial number and its QR code is located on the Device Serial Number ...

Page 7: ...n for all os Linux Yocto Jethro http mx31 de 9 Contains information about Linux BSP with development environment Linux Embedded System Yocto Codename Jethro Version 3 0 includes first information about the bootloader Flash N Go 7 PRODUCT MANUAL SANVITO 3 2 Related Documents and Online Support This document contains operating system specific information The following additional documentations are a...

Page 8: ... Mbit s Host Type A RS 485 1x RS 485 galvanic isolated Miscellaneous Sensors Ambient Light Sensor LED 2 colour status LEDs Audio Audio Internal 2x Speaker 1 0 W RMS 8 Ω Micro Internal Display and Touch Size 10 1 inch 255 85 mm Resolution 1280 x 800 pixel Brightness Typ 420 cd m2 Backlight Lifetime Min 50 000 h Viewing Angle 85 85 85 85 UDRL Color 24 bit 16 7 Mio colors Touch projected capacitive s...

Page 9: ...9 PRODUCT MANUAL SANVITO 4 1 Block Diagram SBC Tbd ...

Page 10: ...t 5 RS 485 6 Expansion Boar Connector PCIe 7 Micro SD card holder 8 USB OTG 9 USB Host 10 Reset 10 PRODUCT MANUAL SANVITO 4 2 Connectors As this manual describes a core version the internal and external interfaces will be mentioned in the following chapter 1 6 8 7 2 10 9 3 4 5 ...

Page 11: ... Level 1 DCIN Plus 24V 2 GND Minus Pin Name Description 1 RS485 1_A RS485 Port 1 2 RS485 1_B RS485 Port 1 3 RS485 1_GND Ground Port 1 11 PRODUCT MANUAL SANVITO 5 1 DC Power Supply 5 2 RS485 5 External Interfaces ACC MT 1 1 ...

Page 12: ... In 1 high side 6 DIN1 Digital In 1 low side 7 DIN2 Digital In 2 high side 8 DIN2 Digital In 2 low side Pin Name Description J1 TX Transmit data plus J2 TX Transmit data minus J3 RX Receive data plus J4 Spare1 Spare 1 J5 Spare1 Spare 1 J6 RX Receive data minus J7 Spare2 Spare 2 J8 Spare2 Spare 2 Sh Shield Schirm 12 1 1 PRODUCT MANUAL SANVITO 5 3 Digital In Out 5 4 Ethernet 1 ...

Page 13: ...ower supply 5V 500mA 2 D Data minus 3 D Data plus 4 GND Ground Sh Shield Schirm Pin Name Description Level 1 VCC Power supply 5V max 500mA 2 D Data minus 3 D Data plus 4 USB Device ID Device ID 5 GND Ground 13 1 1 PRODUCT MANUAL SANVITO 5 6 USB OTG ...

Page 14: ...ription Level 1 DAT3 Data 3 3V 2 CMD Pullup 3 3V 3 GND Ground 0V 4 VDD Supply 3 3V 5 CLK Clock 3 3V 6 GND Ground 0V 7 DAT0 Data 3 3V 8 DAT1 Data 3 3V 9 DAT2 Data 3 3V 10 CD Card detection 3 3V 11 WP Write protection 3 3V 12 COM Common ground 0V Header Micro SD card ...

Page 15: ...GPIO 3 3V 23 GND Ground 24 ETH1_RESET CPU signal for Reset Ethernet 1 3 3V 25 ETH2_RESET CPU signal for Reset Ethernet 2 3 3V 26 UART_RESET CPU signal for Reset UART 3 3V 27 RS485_PWR1 CPU signal for supply rail RS485_1 3 3V 28 RS485_PWR2 CPU signal for supply rail RS485_2 3 3V 29 RS485_PWR3 CPU signal for supply rail RS485_3 3 3V 30 RS485_PWR4 CPU signal for supply rail RS485_4 3 3V 31 GND Ground...

Page 16: ...16 PRODUCT MANUAL SANVITO 5 9 Figure Mainboard ...

Page 17: ... Cable Mounting with Cable Inlet If intended to use on wall cable mounting make sure to replace the slide in modules Therefore remove the pre installed modules Following install the cable inlet modules and fasten the two screws The cables can be stick trough the material ...

Page 18: ...ur screws with sufficient holding force For a flushmounted cable installation consider the position of the flush mount box as shown in the following figure Flush mount box 200 112 100 56 Aufputz Montag 190 90 Unterputz Monta Possible screw positioning 1 Possible screw positioning 2 ...

Page 19: ...19 PRODUCT MANUAL SANVITO After installing the wall holder the device can be hook in Finally fix the device on the wall holder with a screw from the bottom side as shown in the figure ...

Page 20: ...DC Power Supply 10 USB Host 11 Reset Button 12 Factory Reset 13 Status LED 14 Factory Reset 15 Status LED 8 7 A B 2 3 4 5 6 1 5 7 8 2 4 6 1 3 E D C F F D B A E C Redistribution and duplication of this document recovery and exploitationNotification of its contents is prohibited unless expressly permitted Infringements require compensation All rights for the case reserved for patent utility model or...

Page 21: ... Dot shape D 0 25mm ignored ignored Dot shape over all in display area and panel It means Particle Scratch Bubble Dent and others 0 25 D 0 5mm 3 200cm2 1 200cm2 3 D 0 5mm 0 0 Line or spiral shape W 0 07mm ignored ignored Line shape over all in display area and panel It means Particle Scratch Bubble Dent and others 0 07 W 0 1mm L 5mm 3 200cm2 1 200cm2 3 W 0 1mm L 5mm 0 0 Chipped panel edges 0 7mm x...

Page 22: ...on PCB SANVITO 900 4185R SANVITO V2 1 22 PRODUCT MANUAL SANVITO Annex C Hardware Revision Information This document is applicable for all products listed below Hardware Revision Changes Marking on PCB V2 1 initial release SANVITO V2 1 ...

Page 23: ... These markets are subjected to different UL certifications Therefore Garz Fricke have no UL certification for their products To obtain UL certifications the product is designed to respect the following constraints All electronic printed circuit boards are conform to UL standard Garz Fricke do not guarantee to obtain UL certifications Please contact us for further information D 4 Garz Fricke Confo...

Page 24: ...lad to support you Please note that beyond the support hours included the Starter Kit various support packages are available To keep the pure product cost at a reasonable level we have to charge support and consulting services per effort Shipping Address Garz Fricke GmbH Schlachthofstrasse 20 21079 Hamburg Germany In case of returning a product please contact RMA garz fricke com first to get your ...

Page 25: ...opyright symbols does not imply that a product is not protected Additionally registered patents and trademarks are similarly not expressly indicated Drawings All drawings which are shown in this manual are schematic drawings For exact technical drawings please refer to our sales team or product manager All other product or service names are the property of their respective owners All rights reserv...

Reviews: