Turning Off the Detector
Press and hold the button until the OFF countdown
completes, then release the button
Calibrating the Detector
Press and hold the button through the OFF countdown and
the CAL countdown. When prompted, apply gas
Battery Information
Low Battery Warning
The detector will beep, flash,
vibrate and display LOW BAT throughout the last 20
minutes of battery life before automatically turning off.
Charging
Takes 4-6 hours. The detector will cycle the
battery icons and display an approximate percentage.
To turn on the detector, press and hold the button. The unit
will display each sensor’s readings. A chasing “O” indicates
stabilization
When the gas flow is blocked, the detector will go into
alarm and disable the pump. Press the button to reactivate
the pump.
!
Perform a blocked flow test daily and any time the sampling
system is changed to confirm no leaks in the sampling system.
!
DO NOT charge the detector in a combustible atmosphere.
!
DO NOT charge in temperatures outside 0 to 40°C.
Entry
1
2
3
4
5
6
Description
Alarm bar LEDs
Maintenance LED
Alligator Clip
IR Port
Gas Inlet
Filter Window
2
1
12
11
10
3
5
6
7
9
8
4
C22.2 No.152
Intrinsically Safe / Sécurité Intrinsèque
Cl.1 Gr.A,B,C,D; T4 / C1 Zone 0 AEx ia IIC T4 Ga
-20°C
≤
Ta
≤
+50°C 4.2Vdc
Ex ia IIC T4 Ga; IECEx CSA 13.0014X
SEETRON, lnc.
Made in Bucheon,
South Korea
USA 75104
SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
DO NOT CHARGE IN A HAZARDOUS LOCATION
L i
W A R N I N G
C
US
®
0359
Multi Gas Clip
MODEL: MGC-IR-Pump
SN: P4SE000000
Entry
7
8
9
10
11
12
Description
Labels
Gas Exhaust
Charging Port
Button
Audible Port
Display
II 1 G
Stabilization
Fully operational
0*&3XPS