Relay Switching O/P on Alarm Configuration:  

This output will operate a relay that actives when the set alarm point is triggered by an increased gas 
concentration. From factory the default set alarm point is 100ppm or set to the value requested by the 
user at purchase. The alarm point is user adjustable. 

Be cautious when handling the GDA 3160 as there are delicate components that can easily be damaged 

by static discharge. Always observe anti static precautions. 

 

Ensure that the alarm enable jumper (Orange) is on JP6. 

(

The alarm enable jumper has been factory set to on for ver 5.5

.) 

 
If the "

MUTE

" link (

Purple

) is in it will mute the on board buzzer. If the optional mute button is installed 

the on board buzzer can be muted by pressing the button which is located on the front panel (see 
location of the mute button in the picture on page 4). 
 

To set the relay activation alarm point: 

1. Remove the GDA 3160 from the wall to access the back of the sensor unit; 
2. Place a volt meter between test points 1 & 2 (

RED);

 

3. Adjust “RAlarm” POT (

BLUE

) with a small screw driver, to the calculated voltage corresponding to the 

desired alarm point (see formula information below); and 
4. Revert to normal operation. 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1 

Test point 1 &2 (

RED

 

RAlarm 

POT 

(

BLUE

Normally Closed 

    Normally Open 

MUTE 

LINK 

(

Purple

 

Common 

Alarm Enable 

(

Orange

 

Summary of Contents for GDA 3160

Page 1: ...GDA 3160 3100 V5 5 HARDWARE AND ABOVE Refrigerant Gas Detector Operating Manual Copyright Gas Detection Australia Pty Ltd Dec 2017...

Page 2: ...f cable run Screen must be connected to the Earth connection on the connector P1 Power Consumption 300mW average Output Types 4 20mA Standard 0 20mA 0 5v 0 10v User Specified Target Gas Refrigerant R2...

Page 3: ...he further from the potential leeks the more the gas will be diluted Take into account drafts and air movements when mounting the sensor IT IS VERY IMPORTANT THAT THE GDA 3160 IS INSTALLED IN THE MOST...

Page 4: ...rrying capability to suit the length of cable run Screen must be connected to the Earth connection on the connector P1 The Protection Cover Plate is used to protect the main PCB from most cases of sta...

Page 5: ...at this does not affect external equipment LED STATE FUNTION ON Power is present OFF Power is not present LEDs CHASE Sensor is in its initialisation period approx 30 secs but in some sensors this can...

Page 6: ...ve into a maximum of 680 load impedance line and input impedance at 24V Be cautious when handling the GDA 3160 as there are delicate components that can easily be damaged by static discharge Always ob...

Page 7: ...JP6 The alarm enable jumper has been factory set to on for ver 5 5 If the MUTE link Purple is in it will mute the on board buzzer If the optional mute button is installed the on board buzzer can be m...

Page 8: ...in service if the sensor falls below a minimum working standard the o p current will fall to 3 00mA which will be detected at the control unit has a sensor fault Zero point Calibration A manual zeroi...

Page 9: ...Zero 0 5 sec Alternate Blinking at once per second for 4 sec Zero Successful 0 1 sec Fast Blink for 2 sec Zero Failed Solid for 2 sec Manual Calibration Mode Add a jumper to pins 1 and 3 of P3 P4 LED...

Page 10: ...Gas Detection Australia Pty Ltd Page 10 of 12 M 3160 003 1 05 12 2017 Thank You For Supporting Australian Manufactured Products...

Page 11: ...Gas Detection Australia Pty Ltd Page 11 of 12 M 3160 003 1 05 12 2017 Notes...

Page 12: ...Gas Detection Australia Pty Ltd Page 12 of 12 M 3160 003 1 05 12 2017...

Reviews: