15 ELECTRICAL SYSTEM
98
F01568-10
Main work
Warning
Risk of injury
12 V batteries contain harmful substances.
–
Keep 12 V batteries out of the reach of children.
–
Keep sparks and open flames away from 12 V batteries.
–
Only charge 12 V batteries in well-ventilated rooms.
–
Maintain a minimum clearance from inflammable
materials when charging 12 V batteries.
Minimum clearance
1 m (3 ft)
–
Do not charge deeply discharged 12 V batteries if the
charge is already below the minimum voltage.
Minimum voltage before
the start of the charge
9 V
–
Dispose of 12 V batteries with less than the minimum
voltage correctly.
–
Check the battery voltage.
» Battery voltage: < 9 V
–
Do not charge the 12-V battery.
–
Replace the 12-V battery and dispose of the old 12-V bat-
tery properly.
» If the specifications have been met:
Battery voltage:
≥
9 V
–
Connect a battery charger to the 12-V battery. Switch on
the battery charger.
Guideline
Maximum charging voltage
14.4 V
Maximum charging current 3.0 A
Maximum charging time
12 h
Recharge the 12-V battery
regularly when the motor-
cycle is not being used
6 months
Ideal charging and storage
temperature of the lithium-
ion battery
10 … 20 °C (50 … 68 °F)
Battery charger (79629974000)
This battery charger tests whether the 12-V battery retains
its voltage. It is also impossible to overcharge the 12-V bat-
tery with this battery charger. The charging time may be
longer at low temperatures.
This battery charger is only suitable for lithium iron phos-
phate batteries. Read the accompanying
GASGAS Techni-
cal Accessories
instructions.
Summary of Contents for 3215013en
Page 1: ...OWNER S MANUAL 2021 EC 350F Art no 3215013en ...
Page 2: ......
Page 40: ...10 SERVICE SCHEDULE 38 One time interval Periodic interval ...
Page 138: ...23 TECHNICAL DATA 136 Screw in fitting cooling system M24x1 5 18 Nm 13 3 lbf ft Loctite 243 ...
Page 150: ... 3215013en 3215013en 10 2020 Stallhofnerstraße 3 5230 Mattighofen Austria http www gasgas com ...