MDE-4334C Atlas Start-up and Service Manual · April 2008
Page 6-29
Installing the Atlas 9800 CPU Board (M06333KXXXX)
Electronic and Electrical Components
8
The M06333KXXXX CPU board can be configured for various operating conditions using the
jumpers JP1 to JP9 and Switch SW2. Check these jumpers and switch settings and change if
necessary. Jumper settings must be changed with the power to the pump/dispenser “Off”. The
M06333KXXXX CPU board only reads new jumper settings during power-up. For detailed
information on Jumper and Switch Settings for the M06333KXXXX CPU, refer to
on
9
Set new CPU board on the standoffs. Re-install screws removed in step
plastic standoffs, ensure that the metal standoffs are under the mounting holes located between
P2 and P3, and the outside corner next to P5. Carefully push the new CPU board onto the
standoffs before installing the screws.
10
Re-connect all the cables, P1 to P9, and P11, if applicable. Re-connect the DC cable to P10 of
the power supply.
11
Apply power to the pump/dispenser and take note of the display(s). The first set of numbers
displayed will be the software version (for example, 06013), the second set is the software
type (for example, 9800 1), and the third set is the firmware version (for example, 01008).
Ensure that the displayed software type is correct for the pump/dispenser model that the CPU
is installed in (refer to the table below). If it is, proceed to step
. If not, proceed to
on
Displayed Software Type
Corresponding Pump/Dispenser Model
“9800 1“
Corresponds to the 9800Q Software:
9852A/Q, 9853A/Q, 9822A/Q, 9823A/Q/K
“9800 2“
Corresponds to the 9800K Software:
9852K, 9853K
“9840 1“
Corresponds to the 9840Q Software:
9840A, 9840Q
“9840 2“
Corresponds to the 9840K Software:
9840K
“9850“
Corresponds to all 9850 Software:
9850A, 9850Q, 9850K
12
Re-assemble the pump/dispenser by proceeding to
Accessing the Electronic Components
on
and follow the steps in the reverse order.