background image

13

 

SPECIFICATIONS

 

Measurement Range & 

Accuracy 

CO

2

: 1%, 5%, 10%, 20%, 30%, 100% 

CO: 0~1,000ppm 
O

2

: 0~25%

< 2% FS / 0.1 mbar 

CH

4

: 5% 0-

1%: ≤±0.1%

 

RH: 0~100%, ±3% @25°C (20~80%RH), others ±5%

 

Temperature: 0~50°C,±1

 

Barometer: 50~110kPa, 

±

0.4kPa 

Display Resolution 

CO

2

: 1ppm, 10ppm, or 100ppm 

CO: 1ppm 

O

2

: 0.01% 

CH

4

: 0.01% 

RH: 0.01% 

Temperature: 0.01°C

 

Barometer: 0.1mmHg 

Alarm Volume 

80db±5%@10cm

 

Operating Conditions 

0~50°C(32~122°F), 0~95%RH, non

-condensing 

Storage Temp. 

-

20~60°C(

-

4~140°F)

RS485 CO2Meter Internal

RS485 ModBus BR19200

 

Power Supply 

Rechargeable Battery: Li-

ion 18650 3.7V

 

AC Adapter: 5V±5% >1A, 100~240 VAC, 50/60 Hz

 

Storage Capacity 

depend on SD card capacity (max.16G SD card) 

Weight 

480g (1.05 lbs.) 

- without batteries 

Dimensions 

225.8x99.6x55 mm (8.9 x 3.9 x 2.2 in.)

 

CM-1000 Pump Pneumatic Data

Max. Flow 

500 ml/min 

Max intermittent duty 

380 to 400 mbar

 

Max. continuous 

pressure 

150 mbar 

Max. restart pressure 

150 mbar 

Max. vacuum 

-360 to -400 mbar

Max. restart vacuum 

-150 mbar

Electrical / General Data 

Motor type 

Standard DC 

Rated power 

3.5 to 5 V/90 mA 

Protection class 

IP00 

Ambient Temperature 

10 to 50°C

 

Media Temperature 

10 to 50°C

 

Weight 

17g (0.03lb) 

Note: 

After power-on, it takes 20 minutes for the device to stabilize and measure the 

temperature and relative humidity, accurately.

 

EMC/RFI: 

Readings may be affected if the unit is operated within radio frequency 

electromagnetic field strength of approximately 3 volts per meter, however the 

performance of the instrument will not be permanently affected. 

Summary of Contents for CM-1000-00-00-00-25

Page 1: ...Operation Manual Popular Models 100 CO2 CM 1000 00 00 25 00 10 CO2 CM 1000 00 00 00 25 25 O2 CM 1000 00 00 52 00 25 O2 100 CO2 CM 1000 00 52 25 00 Up to 64 Customizable Sensor Configurations Copyrigh...

Page 2: ...GUIDE 7 Powering Operation 7 DATA LOGGING 8 SETTINGS 9 DISPLAY SETTINGS 9 Date Time 1 1 9 Custom Settings 9 USING THE FILTERS 10 CALIBRATION 11 WHY IS CALIBRATION REQUIRED 11 FACTORY CALIBRATION 11 O...

Page 3: ...our local community CO2Meter Inc appreciates your business and looks forward to working with you and your team in the future Please take some time to read through this manual to become familiar with...

Page 4: ...Trap can be purchased separately This filter will allow free flow of sampled air while keeping moisture out of the meter Note Please contact our technical support staff for more details about these ac...

Page 5: ...sting of fire suppression systems The devices built in micro pump ensures reliable operation and consistent readings based on user selected time intervals PRINCIPAL OF OPERATION The sensors inside thi...

Page 6: ...eperiod LCD Display The Full Color Liquid Crystal Display LCD shows the following features CO2 concentration level in parts per million ppm or O2 CO CH4 concentration levels in percentage format RH AM...

Page 7: ...Follow these instructions to ensure proper set up 1 After powered on when pump is activated the device will measure the data in real time 2 Before getting started you need to enter the settings screen...

Page 8: ...bing and filters as required to the top ports see image on page10 3 To begin logging press and hold the PUMP button The inner square of the SD Card Icon in the top right hand corner of the screen will...

Page 9: ...en auto rotate Yes No YES Backlight level 1 32 The larger the number the brighter the screen 11 Background color There are a total of 4 background colors Black Backlight time 10 999 sec Backlight disp...

Page 10: ...y vacuum effect push it through the sensing chamber and then exhaust the air outside the meter through the outlet port Below are examples of the options for exhausting the sampled air closed vs open l...

Page 11: ...hable difference between 1 point and 2 point calibration methods One point sensor calibration involves applying one reference gas whereas 2 point calibration is done by provided two reference gases to...

Page 12: ...the UP E and Down H arrows at the same time to enter the specific Sensor Calibration page 7 Press the Enter button J to highlight Target Sensor inRed 8 Press the Down arrow button H to scroll through...

Page 13: ...ard Weight 480g 1 05 lbs without batteries Dimensions 225 8x99 6x55 mm 8 9 x 3 9 x 2 2 in CM 1000 Pump Pneumatic Data Max Flow 500 ml min Max intermittent duty 380 to 400 mbar Max continuous pressure...

Page 14: ...libration measurements or data logging please reference the settings section to adjust backlight auto power off from default settings LCD Screen Troubleshooting During Use If the user experiences issu...

Page 15: ...he device rises The temperature and humidity sensors are affected Currently measurements are only for reference After batteries are fully charged and the device cools down measurements are reliable 3...

Reviews: