www.desatech.com
9
113048-01F
INSTALLATION
Continued
Figure 7 - Removing Front Panel Of
Heater
Figure 6 - Mounting Bracket
INSTALLING HEATER TO WALL
Mounting Bracket
Locate mounting bracket in heater carton. Remove
mounting bracket from heater carton.
Removing Front Panel Of Heater
1. Remove the four painted screws, two on each
side of front panel.
2. Pull bottom of front panel forward, then out.
3. Remove any remaining packaging materials.
Methods For Attaching Mounting Bracket
To Wall
Only use last hole on each end of mounting bracket
to attach bracket to wall. These two holes are 14
inches apart from their centers. Attach mounting
bracket to wall in one of two ways:
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to Wall Stud: This method provides the
strongest hold. Insert mounting screws through
mounting bracket and into wall studs.
Attaching to Wall Anchor: This method allows you
to attach mounting bracket to hollow walls (wall
areas between studs) or to solid walls (concrete
or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for the
mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall where heater
will be located. Make sure mounting bracket
is level.
WARNING: Maintain mini-
mum clearances shown in Figure
8. If you can, provide greater
clearances from floor and join-
ing wall.
2. Mark screw locations on wall (see Figure 8).
Note:
Only mark last hole on each end of
mounting bracket. Insert mounting screws
through these holes only.
3. Remove tape and mounting bracket from
wall.
30,000 Btu/Hr Blue Flame Models
3 Plaque Infrared Heaters
20,000 Btu/Hr Blue Flame Models
Figure 8 - Mounting Bracket Clearances
8"
(20.3
cm)
Min.
A
dj
oi
ni
ng
W
al
l
A
dj
oi
ni
ng
W
al
l
Only Insert Mounting
Screws Through Last
Hole On Each End
Only Insert Mounting
Screws Through Last
Hole On Each End
Floor
Floor
14" (35.6 cm)
14" (35.6 cm)
18
3
/
4
"
(47.6 cm)
Min.
18
3
/
4
"
(47.6 cm)
Min.
12"
(30.4
cm)
Min.
8"
(20.3
cm)
Min.
A
dj
oi
ni
ng
W
al
l
A
dj
oi
ni
ng
W
al
l
Only Insert Mounting
Screws Through Last
Hole On Each End
Only Insert Mounting
Screws Through Last
Hole On Each End
Floor
Floor
14" (35.6 cm)
14" (35.6 cm)
18
3
/
4
"
(47.6 cm)
Min.
18
3
/
4
"
(47.6 cm)
Min.
12"
(30.4
cm)
Min.
18
3
/
4
"
(47.6 cm)
Min.
16"
(40.6 cm)
Min.
14" (35.6 cm)
18
3
/
4
"
(47.6 cm)
Min.
12"
(30.4
cm)
Min.
A
dj
oi
ni
ng
W
al
l
14" (35.6 cm)
A
dj
oi
ni
ng
W
al
l
Only Insert Mounting
Screws Through Last
Hole On Each End
Only Insert Mounting
Screws Through Last
Hole On Each End
Floor
Floor
5 Plaque Infrared Heaters