6
7
6
TEST FIRING HEATER
Test fire heater, following the lighting instructions on heater post. Leak test all gas connections with soapy water. Soap
bubbles indicate gas leakage.
DO NOT use a match to test for gas leaks.
TROUBLE SHOOTING
Problem
Possible causes
Main burner will not light
No gas
Low gas pressure
Blockage in orifice
Manual valve no in LOW or HIGH position
Note: If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
White smoke may appear around the emitter grid during
the first minute of initial firing.
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Any modifications or adjustments made to product without prior authority from
the manufacturer will void any warranty claims. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
WARNING
LIGHTING INSTRUcTIONS
Step 1
Ensure that the control knob is off. Slowly open the gas
cylinder valve.
Step 2
Push in control knob and turn anti-clockwise to HIGH
whilst simultaneously pushing the ignitor button several
times.
Step 3
Check for flame at the burner. If burner does not light
immediately turn control knob to OFF position and try
again from the start. Allow 30 seconds between ignition
attempts for gas to dissipate. Several attempts may be
necessary.
Failure to follow this lighting procedure may result in
flame roll out beyond the emitter grid.
Step 4
With the burner alight keep control knob depressed for
15 seconds.
Step 5
For minimum heat push in and turn the control knob to
LOW.
Step 6
To turn heater off, turn the control knob to OFF.
Pus
h to
tu
rn
OFF
Pus
h to
tu
rn
OFF
LOW
HIG
H
LOW
HIG
H