8
Operating instructions
Mode selection keys (wood firing mode)
With the switch nr. 13 you can connect or disconnect the sy-
stem pump/boiler load from the mains electrical system.
-
With the switch in the ‘0’ position the system pump is
not switched on.
-
With the switch in the ‘II’ position the system pump is
connected to the mains electricity supply.
With the switch nr. 12 you can connect or disconnect the fan
from the mains electrical system.
-
With the switch in the ‘0’ position the fan is not switched
on.
-
With the switch in the ‘I’ position the fan is connected to
the mains electricity supply but it will not run. It will start run-
ning only after the upper loading door has been closed.
With the switch 22 it is possible to select the operation mode
(wood or the back-up gas or oil fired boiler).
-
Place the switch into the’0’ position (wood firing mode)
Note:
The upper door is open in order to load the
wood and the fan is off. Proceed with igniting
the wood as described in paragraph 6.4.
The opening of the loading door activates a control timer, via
a microswitch, with a 30 minutes default value, which can be
increased by another 30 (this can only be carried out by qua-
lified personnel).
If the boiler does not reach the minimum temperature (about
65°C) within the foreseen time (control timer), the fan and re-
cycling pump will be turned off.
Panel connected to the mains electricity supply, but… the
boiler is not running.
Therefore repeat the lighting procedure.