Setup can be  done trough a data terminal or  trough  a pushbutton and  LED light. Full 
functions are only available if programmed trough the data terminal.  
 
In  both  cases,  first  of  all  you  should  decide  if  you  will  use  one  or  two  channels  for 
control,  and  then  setup  your  transmitter  accordingly.  Check  with  a  servo  first  that  the 
transmitter is operating as it should and to identify the RX channels used. 
 

 

Double channel operation

. The 

Gear In 

input control the retract operation and the 

Brake

 input control the brake. 

 

 

Single channel operation

: The 

Gear In

 input control both the  gear  and the brake. 

The operation similar to a turbine engine control where raising the trim enable the 
engine to run and the stick throw regulate the engine power.  In this case, first the 
gear will be operated and then the brake. For example, you can setup a channel that 
from –100% to –75% activate the gear and from –75% to +100% regulate the brake 
power. 

 
The following setup procedure assumes the use of a Xicoy data terminal, please jump to 
the “Manual Setup” section for the pushbutton and Led setup procedure. 
 
 

Setup using a data terminal 

Connect the data terminal (Same model as used by Xicoy V10 ecus) on the socket at left 
side of 

Gear In

 input.  

 
You can navigate trough the different menus by the buttons on the left side of the box, 
and values are changed using the + and – buttons on the right side. 
 
First  screen  displayed  show  the  status  (gear  up,  gear  down,  etc),  the  battery  voltage, 
power of the brake, and, during motor operation, the amperage to each of the motors. 
 
Second  screen  display  the  RC  signals  measured  from  the  receiver.  You  can  check  that 
the  RX  connection  is  working  and  the  measured  values  change  when  the  transmitter 
controls are operated. Standard RC signal go from 1000 to 2000uS, 1000us typically is 
displayed on RC transmitters as –100% 1500uS 0% and 2000uS as +100%. Due at display 
space the numbers are  divided by 10, so a  measured signal of 1400uS is displayed as 
“140”.  You  can  check  that,  when  operating  the  transmitter,  the  reading  change 
accordingly. 
 
On  third  screen  you  can  scroll  trough  the  different  programming  sections.  Select  the 
area you want to program by pressing the “+” button. 
 

Summary of Contents for Xicoy LGC 13C

Page 1: ...LGC 13C Users Guide Plaça Pere Llauger I Prim nau 18 08360 Canet de Mar Barcelona Catalonia Spain E mail sales xicoy com Fax 34 93 794 27 74 web www xicoy com Copyright 2019 Xicoy Electronica SL All Rights Reserved Manual contents design Gaspar Espiell ...

Page 2: ...retracted mode programmable center sense of movement and gain on extended position Single or dual channel mode Programmable delay for extension and retraction of all gears independently Easy programming trough a LCD display Small size and lightweight Installation Thanks the small size and lightweight of the unit it can be placed in any place on the model We recommend a place where the wiring to th...

Page 3: ...s beyond repair Output for the door servos Connect the 3 servos to the outputs on the unit You can connect more than one servo to each output using a Y lead Output to the steering servo Connect the steering servo to Steer Out if used Radio inputs You can choose to use a single channel to control the gear and brake or separated channels Gear input channel should be always connected for operation br...

Page 4: ...xcessive causing the receiver to switch off c The power input pin of the Gear and Brake inputs are internally connected together This could cause a malfunction by connecting different voltages together For example if you connect the Gear Input directly to the receiver that is powered at 5V and the brake input to a battery regulator that supply 6V then the 6V supply will flow trough the unit to the...

Page 5: ...oy data terminal please jump to the Manual Setup section for the pushbutton and Led setup procedure Setup using a data terminal Connect the data terminal Same model as used by Xicoy V10 ecus on the socket at left side of Gear In input You can navigate trough the different menus by the buttons on the left side of the box and values are changed using the and buttons on the right side First screen di...

Page 6: ...ter switch or slider of the brake channel or on the gear channel if you use the single channel option in the position you wish that the brake be unpowered Press the button The controller will store the current signal received as Brake OFF command Picture 4 Note that if in this step the controller does not detect a valid signal in the brake input then it will assume a single channel operation mode ...

Page 7: ...fferent positions for each output Gear Up position The position you wish that the servo be driven when the gear is retracted Typically is a closed door Gear Down position The position you wish that the servo be driven when the gear is extended Depending on model type could be a opened or closed door Motor ON position The position of the doors when the retracts are moving typically open The setup o...

Page 8: ...h the TX to the position you want that it to be when the gear is in movement and press the button to store the setting Usually is the same position as the gear down position in the OPENED CLOSED sequence but also it allow programming an over travel the door opens more during gear operation to give extra clearance to the wheel and legs but return to scale position when the gear is fully extended Se...

Page 9: ...r is operated since the Gear Up command is selected Second screen is the delay time on the same gear main left motor operation when gear down is selected Next screens adjust same delays for right mains and nose gear Please note that you can use this function to insert a delay from door operation to gear operation by programming same delay on all 3 motors Steering servo processor The steering servo...

Page 10: ...the travel and sense it is possible that the centering need a new adjust just go back to previous adjustment by the menu buttons Motor adjust This last section of adjustment allows adapting the unit to different motors These adjustments are not available in some of the units that are setup by motor manufacturer First adjustment is Motor Cut Amperage Picture 9 Maximum value is 2 5A This is the thre...

Page 11: ...e currently command received from the transmitter Switch On delay There is some intelligence build in the controller to prevent unwanted gear operation when switching on the receiver and power supply At power up the controller will wait during 3 seconds waiting for the receiver to boot and stabilize the outputs ignoring any glitches that it could generate during this time After these 3 seconds the...

Page 12: ...nit will detect if signal present on Brake In if not will assume single channel mode 4 blinks Brake maximum 5 Blinks Steering servo retracted position NOTE Executing this procedure will set all remaining adjustments to the factory defaults all delays door servo positions steering servo adjustments will be reset to default This procedure allow to use the controller in simple models without the need...

Reviews: