Group Four Transducers22 Deer Park Drive,E. Longmeadow, MA 01028www.groupfourtransducers.com
Phone : (800) 419 1444Fax : (413) 525 -6182sales@group-4.com
Rev 0
8
5.
MENU
5.1 Structure of the Menu
Page 1: ...CYLINDER WEIGHT SCALE GQ CWS INSTRUCTIONS...
Page 2: ...BATTERY INSTALLATIONINSTRUCTIONS 4 3 ELECTRICAL CONNECTIONS 5 4 KEY FUNCTIONS 6 4 1 Tare Zero lb to kg conversion 6 FUNCTION 7 7 7 7 5 MENU 8 5 1 Structure of the Menu 8 5 2 Access to Main Menu 9 5 3...
Page 3: ...ducers 22 Deer Park Drive E Longmeadow MA 01028 www groupfourtransducers com Phone 800 419 1444 Fax 413 525 6182 sales group 4 com Rev 0 3 1 MECHANICALCONSTRUCTIONS 1 1 Outlinedimensions All Dimension...
Page 4: ...444 Fax 413 525 6182 sales group 4 com Rev 0 4 2 BATTERY INSTALLATIONINSTRUCTIONS Remove battery cover as below image Verify battery polarity as labeled in battery holders Lithium Ion 3 7V button top...
Page 5: ...groupfourtransducers com Phone 800 419 1444 Fax 413 525 6182 sales group 4 com Rev 0 5 3 ELECTRICAL CONNECTIONS Use only provided battery charger to charge the Lithium Ion 18650 rechargeable batteries...
Page 6: ...in the two main Key Weighing Display functionality Menu Display functionality Menu SELECT Move to Menu Select an item ZERO UP Set Scale ZERO Move UP When entering number the key is used to increase t...
Page 7: ...oint to that which was will return the 4 4 Set the tare point this function will activate the net weighing function by storing the current the net weighing mode and restores the current zero The weigh...
Page 8: ...Group Four Transducers 22 Deer Park Drive E Longmeadow MA 01028 www groupfourtransducers com Phone 800 419 1444 Fax 413 525 6182 sales group 4 com Rev 0 8 5 MENU 5 1 Structure of the Menu...
Page 9: ...to Main Menu In weighing window by pressing the Menu button it allows to access to the scale menu and button functionality has been changed to reach menu functionalities as below 5 3 Change numeric pa...
Page 10: ...isplayed in this section and one of them is flashing The flashing zero is a changeable digit right digit and begins blinking that digit The value of the blinking digit can be c v Using the Select butt...
Page 11: ...Longmeadow MA 01028 www groupfourtransducers com Phone 800 419 1444 Fax 413 525 6182 sales group 4 com Rev 0 11 8 tton 9 Enter the maximum capacity including buttons 10 11 times for back to normal wei...
Page 12: ...e stays Turn on Default N OFF Auto power off The scale can be set up to automatically power down after a period of no activity Weight motion or any press of the keyboard is enough to keep the instrume...
Page 13: ...should be enter to enable this setting Settings Factory Default Setting Backlight N OFF Auto power off N OFF Gross Net Net Maximum Capacity 999999 Minimum Capacity 999999 Zero range 0 Display Step Siz...
Page 14: ...it of measure can be selected as lb or kg CZ Set the calibration zero point this is the reference point for all weight calculations Make sure there is no any weight on the scale when performing this f...
Page 15: ...n 1 Options 1 Display output count step up or down by 1 2 Display output count step up or down by 2 5 Display output count step up or down by 5 10 Display output count step up or down by 10 20 Display...
Page 16: ...nverter therefore have an effect on all aspects of weigher operation Filter Mode There are two adjustable digital Low pass filters to be set in filter mode setting Options IIR 18 0 25 Hz FIR 19 8 2 5...
Page 17: ...ion facility provides a means of disabling certain functions whenever a condition of cannot fluctuate by No Motion Range This is the range within which the weighing signal is allowed to fluctuate and...
Page 18: ...isplay step size The zero can only be tracked to Zero range A value of zero turns off the zero tracking Default 0 Store Zero Value This function sets the zero mode to volatile off or non volatile on I...
Page 19: ...s group 4 com Rev 0 19 6 CALIBRATIONPROCEDURE Step1 Select Quick Calibration Step Step3 Enter the decimal point that need to set 0 3 Step Step5 Enter the weight value that going to be used for calibra...
Page 20: ...4 OFF Stage 2 Bulk charge using charger highest rated current for the type of battery in use until it reaches 80 capacity LEDs 1 4 Blinking Sequentially Stage 3 Constant voltage the output voltage is...
Page 21: ...Plug in charger to AC socket all the lamp will be blinking sequen LED ON 2 Please Disconnect and Check 3 Depending connected to battery left indefinitely Warning 1 This charger is designed for charge...