The
Wallcon
boilers are supplied fully assembled in a
strong cardboard box.
After having unpacked the boiler check that it is intact and
undamaged.
Keep the packaging material (cardboard box,
plastic bags, polyester protection etc
.) out of
the reach of children as they can be
dangerous.
GASSERO refuses all liability for injury to persons,
animals or damage to property deriving from
not having respected the above mentioned
recommendations.
In the packaging, in addition to the boiler, you can also find
the following contents:
- Installation and service manual
- Warranty card
- Flue adapter for smoke evacuation
4.1.2 TRANSPORT
CAUTION: Damage to the installation due to
impacts.
The boiler contains parts which can be
damaged by impacts.
During further transport all parts must be
protected against impacts.
Obey the transport symbols and
instructions on the packaging.
To lift and carry the boiler,
place one hand at the bottom of the
boiler and the other hand on its top.
CAUTION: Damage to the unit due to
it being lifted and carried incorrectly.
Do not hold the boiler over the control
panel to lift and carry it.
Place the boiler in its packaging on the handtruck and secure
it with a strap if necessary.
Carefully transport the boiler to the installation
place.
The
Wallcon
Boiler must be secured to a solid brick
or concrete wall using the wall hanging brackets.
For installation:
- Position the bracket on the wall using correct
level to make sure that the holes are perfectly
horizontal(1)
- Mark the fastening holes on the wall (1)
- Drill the holes and insert the expansion plugs(2)
- Fasten the bracket to the wall using the screws
- Hook the boiler to the bracket.
4.1.3 MOUNTING
Instructions for the installer
11
4
INSTRUCTIONS FOR THE INSTALLER
4.1
INSTALLATION
4.1.1
PACKING
- Wall hanging brackets
1
2
RESET