Instructions for the installer
Wallcon 42
B23 C13
C33 C43,C53
C63,C83
Air intake dia.(mm)
Flue duct dia.(mm)
Max. length (m)
p at Max. Qn (Pa)
80
80
30
100
125
80
2
125
80
2
80
80
30
100
100
100
Only use original GASSERO flue gas discharging
systems.
Flue installations must be done by authorized person.
Flue installations must be done according to local
ventilation requirements.
21
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
It is important that the position of the terminal allows
the free passage of air at all times.
The air supply and the flue gas exhaust must meet the
applicable general regulations. Please consult the
instructions provided with the flue terminal kits prior to
installation.
The flue for installations in excess of 67 kW must be
installed in accordance with the recommendations of
IGE UP10.
Wallcon 50
B23 C13
C33 C43,C53
C63,C83
Air intake dia.(mm)
Flue duct dia.(mm)
Max. length (m)
p at Max. Qn (Pa)
80
80
30
140
125
80
2
125
80
2
80
80
30
140
140
140
Wallcon 67
B23 C13
C33 C43,C53
C63,C83
Air intake dia.(mm)
Flue duct dia.(mm)
Max. length (m)
p at Max. Qn (Pa)
80
80
25
170
125
80
2
125
80
2
80
80
25
170
170
150