It is your responsibility to:

• Regularly inspect and make necessary repairs to

product in order to maintain proper operation.

• Make sure that pressure and vacuum is released

from product before starting maintenance.

Check intake and exhaust filters after first 500 hours of

operation. Clean filters and determine how frequently

filters should be checked during future operation. This one

procedure will help to assure the product’s performance

and service life.

General Maintenance

1.

Remove end cap and filters. Inspect filters for

rips,tears, cuts, brittleness and excessive foreign

material.

2. Clean filters if in good condition with

compressed air. Re-inspect for wear conditions.

Set filters aside.

3. Check both internal and external filter felts (#8 and

#11 on exploded view) for foreign material. If felts

are dirty or worn, replace with new felts.

4. Check condition of O-ring on internal filter. It should

be soft and flexible. Replace if it is not.

5. Remove and inspect muffler box. Clean box. Set

box aside. (Not all models have a muffler box.)

6. Check gasket for cracks or tears. Install new gasket

if any cracks or tears appear. Replace gasket.

7. Reinstall muffler box. Torque bolts to 90-120 in. lb.

8. Reinstall filters or install new filters if required.

Reinstall end cap finger tight.

MAINTENANCE

Option 2

1. Remove six end plate bolts. (See exploded view.)

2. Use a small hammer to carefully tap on end plate to

remove. Do not use a screwdriver to pry off.

3. Check that vanes are moving freely in and out of

vane slots. Replace vanes if more than 50% of the

vane extends past the vane slot.

4. Remove vanes and clean both sides with fine emery

cloth. Clean end-plate with fine emery cloth.

5. Flush vanes with solvent and remove all

solvent from vanes.

6. Flush body, rotor and end plate with solvent, then

remove all solvent from each part.

7. Check body, rotor and end plate for scoring. If each

part is clean and shows no signs of scoring,

re-install parts. If scoring appears,

send unit to factory or replace with new part(s).

8. Insert vanes, checking that the bevel edges are in

the correct direction.

9. Replace end plate. Torque bolts to 90-120 in. lb.

10. Check gasket for damage.

11. Reinstall muffler box. Torque bolts to 90-120 in. lb.

Check that all external accessories such as relief valves

and gauges are attached to cover and are not damaged

before re-operating product.

Flushing

Flushing this product to remove excessive dirt, foreign

particles, moisture or oil that occurs in the operating

environment will help to maintain proper vane

performance. There are 2 options for this operation.

If Option 1 does not remedy your problem, go on to

Option 2.

Use only Gast Flushing Solvent or other non-petroleum

based flushing solvent. Do Not use kerosene or ANY

other combustible solvents to flush product.

c

Disconnect electrical power supply cord before

performing maintenance on this product.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

Electrical Shock Hazard

WARNING

Option 1

You will need 2 pipe nipples at least 4 inches long with

appropriate thread size for the unit involved. No nipples

are needed if the unit does not have a muffler box.

1. Remove filter and muffler cap (#9).

2. Remove 5 bolts. Use a small hammer to tap on

muffler box to remove it. Attach pipe nipples

where muffler caps were removed.

3. Start product and add flushing solvent to the inlet

port. If using liquid solvent, pour several

tablespoons directly into the inlet port. If using Gast

spray solvent, spray for 5-10 seconds into inlet

port. Place towel over exhaust port to clean up

solvent.

4. Plug inlet port for 20-30 seconds. Listen for

changes in the sound of the pump. If pump sounds

smooth, go to next step. If pump does not sound

like it is running smoothly, installing a Service Kit will

be required (See Service).

5. Release vacuum.

6. Repeat steps 3-5 three or four times.

If Option 1 is not successful, remove the end plate and

examine.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage.

Flush this product in a well ventilated area.

Do Not use kerosene or other combustible solvents

to flush this product.

WARNING

Injury Hazard

Wear eye protection when flushing this product.

Failure to follow these instructions can result in

eye injury or other serious injury.

Summary of Contents for AT03 Series

Page 1: ...ease packed Use of petroleum or hydrocarbon products will reduce carbon vane service life Thank you for purchasing this product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free service PART NO 70 299 G379 REV C AT03 AT05 SERIES OILLESS COMPRESSORS OPERATION MA...

Page 2: ...ced voltage conditions The wiring diagram attached to the product provides required electrical information Check that power source is correct to properly operate the dual voltage motor It is your responsibility to operate this product at recommended pressures or vacuum duties and room ambient temperatures Start Up If motor fails to start or slows down significantly under load shut off and disconne...

Page 3: ...20 in lb 10 Check gasket for damage 11 Reinstall muffler box Torque bolts to 90 120 in lb Check that all external accessories such as relief valves and gauges are attached to cover and are not damaged before re operating product Flushing Flushing this product to remove excessive dirt foreign particles moisture or oil that occurs in the operating environment will help to maintain proper vane perfor...

Page 4: ...ollow proper shutdown procedures to prevent product damage NEVER ADD OIL TO THIS OIL LESS PUMP 1 Disconnect plumbing 2 Operate product for at least five minutes without plumbing 3 Run at maximum vacuum for 10 15 minutes 4 Repeat step 2 5 Disconnect power supply 6 Plug open ports to prevent dirt or other contaminants from entering product c Disconnect electrical power supply cord before installing ...

Page 5: ...DESCRIPTION QTY GAST PART 1 BODY 1 AK500 2 VANE 4 AH850A 3 SHROUD 1 AK502B 4 END PLATE 1 AK501 5 GASKET 1 AK521 6 MUFFLER BOX 1 AK519 7 O RING 2 AK473 8 FELT 2 AK524 9 END CAP 2 AK510 10 END CAP FILTER 2 AK526 ASSEMBLY 11 FILTER MUFFLER 1 B343B 12 FOOT SUPPORT ASSM 1 AT209 13 FELT SUPPORT 1 B347 14 FELT FILTER 2 B344A 15 SCREEN CAP 1 AJ571 16 TOLERANCE RING 1 AH775B 17 ROTOR 1 AF105 18 GASKET AMBE...

Page 6: ... FOR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REME...

Page 7: ... Clean or replace G G G Vacuum line collapsed Repair or replace G G G Relief valve set too high Inspect and adjust G G Relief valve set too low Inspect and adjust G G G G Plugged vacuum pressure line Inspect and repair G G Vanes sticking Clean or replace G G Vanes worn Replace G G G G Foreign material in pump Inspect and clean G G G G Motor not wired correctly Check wiring diagram and line voltage...

Page 8: ...1012 www gasthk com Gast Manufacturing Inc P O Box 97 2300 Highway M139 Benton Harbor MI 49022 Ph 269 926 6171 FAX 269 925 8288 www gastmfg com www gastmfg com ISO 9001 14001 CERTIFIED Registered Trademark Trademark of Gast Manufacturing Inc Copyright 2002 Gast Manufacturing Inc All Rights Reserved Gast Group Limited United Kingdom Unit 11 The I O Centre Nash Road Redditch B98 7AS United Kingdom p...