background image

In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an
escape wire for the electric current. This product may
be equipped with a power supply cord having a
grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.

Check with a qualified electrician or serviceman if
the grounding instructions are not completely
understood, or if you are not sure whether the
product is properly grounded. Do not modify the
plug provided. If it will not fit the outlet, have the
proper outlet installed by a qualified electrician.

INSTALLATION

c

Disconnect electrical power at the circuit breaker
or fuse box before installing this product.

Install this product where it will not come into
contact with water or other liquids.

Install this product where it will be weather
protected.

Electrically ground this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

Plumbing

Remove plug from the OUT port. Connect with pipe
and fittings that are the same size or larger than the
product’s port.

Accessories

Install relief valve and gauge at outlet to monitor
performance. A check valve may be required to
prevent back streaming through the compressor.

Motor Control
It is your responsibility to contact a qualified
electrician and assure that the electrical installation
is adequate and in conformance with all national
and local codes and ordinances.

Correct installation is your responsibility.

Make sure

you have the proper installation conditions and that
installation clearances do not block air flow.

Mounting

This product must be installed on a flat, horizontal
surface. Mounting the product to a stable, rigid
operating surface and using shock mounts will reduce
noise and vibration.

WARNING

DANGER

Your safety and the safety of others

is extremely important.

We have provided many important safety messages
in this manual and on your product. Always read
and obey all safety messages.

This is the safety alert symbol. This symbol

alerts you to hazards that can kill or hurt you and
others. The safety alert symbol and the words
“DANGER” and “WARNING” will precede all safety
messages. These words mean:

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the safety instructions are not
followed.

2

c

This product must be properly grounded.

Do not modify the plug provided. If it will not
fit the outlet, have the proper outlet installed
by a qualified electrician.

If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire
to either flat blade terminal. The wire with
insulation that is green with or without yellow
stripes is the grounding wire.

Check the condition of the power supply wiring.
Do not permanently connect this product to
wiring that is not in good condition or is 
inadequate for the requirements of this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

ELECTRICAL CONNECTION

Summary of Contents for DDL15

Page 1: ...ther liquids must be filtered out Oil less compressors require NO lubrication Consult your Gast Distributor Representative before using at high altitudes www gastmfg com Registered Trademark Trademark...

Page 2: ...ances Correct installation is your responsibility Make sure you have the proper installation conditions and that installation clearances do not block air flow Mounting This product must be installed o...

Page 3: ...ded Plug Grounding Pin Grounded Outlet 120 volt grounded connectors shown 220 240 volt grounded connectors will differ in shape DIAGRAM A OPERATION Injury Hazard Use only recommended air handling part...

Page 4: ...ous injury WARNING SAVE THESE INSTRUCTIONS WARNING Read and follow all safety instructions To guard against injury basic safety precautions should be observed DANGER To avoid possible electrical shock...

Page 5: ...ll help to assure the product s performance and service life Cleaning Do Not use kerosene or ANY other combustible solvent to clean product To clean the air filter Recommended once every six months 1...

Page 6: ...N A DDL15B K890 N A DDL30 K887 K932 K891 DDL30B K887 K932 N A DDL40 K887 K932 K891 DDL40B K887 K932 N A DDL60 K888 K931 K891 DDL80 K888 K931 K891 DDL120 K889 K930 K892 DDL150 K889 K930 K892 DBP25 K94...

Page 7: ...ousing back with the four screws on IMPORTANT To open the upper housing please make sure you have unplugged the power cord before opening 1 Loosen the four screws around the upper housing and take the...

Page 8: ...13 DIAPHRAGM FRAME 2 14 U NUT 2 15 CHECK VALVE 4 16 L TUBE 2 17 DIAPHRAGM HOUSING 2 18 CHAMBER SEAL ROUND 2 19 CHAMBER SEAL OVAL 2 20 SIDE COVER STEEL 2 21 CORD PROTECTOR 1 22 STEEL PLATE 1 23 GASKET...

Page 9: ...21 STEEL PLATE 1 22 GASKET 1 23 LOWER HOUSING 1 24 RUBBER FEET 4 25 CORD RELIEF 1 26 POWER CORD 1 9 NO DESCRIPTION QTY 1 TOP SCREW 1 2 FILTER COVER 1 3 FILTER 1 4 UPPER HOUSING 1 5 COIL COVER 1 6 SAF...

Page 10: ...1 10 ELECTORMAGNET 2 11 WIRE STOPPER 1 12 COIL FRAME 1 13 VIBRATION CONTROL RUBBER 4 14 ACTIVATING ARM 1 15 DIAPHRAGM 2 16 DIAPHRAGM FRAME 2 17 U NUT 2 18 DIAPHRAGM HOUSING 2 19 CHECK VALVE 8 20 GASKE...

Page 11: ...pair or replace Relief valve set too high Inspect and adjust Relief valve set too low Inspect and adjust Plugged pressure line Inspect and repair Low voltage won t start Check power source Voltage wro...

Page 12: ...SSED OR IMPLIED BY ANY LITERATURE DATA OR PERSON GAST S MAXIMUM LIABILITY UNDER THIS EXCLUSIVE REMEDY SHALL NEVER EXCEED THE COST OF THE SUBJECT PRODUCT AND GAST RESERVES THE RIGHT AT ITS SOLE DISCRET...