26
|
Setting up two-stroke welding mode
Mode two-stroke is set up when the machine is switched off and there is
no LED on such.
Setting two-stroke SPOTTING
Press button until you switch on LED SPOTTING in the picture.
Mode two-stroke spotting is adjusted.
Setting two-stroke PULSE
Press button until you switch on LED PULSE.
Mode two-stroke pulse is adjusted.
Setting SPOTTING time
Press button SET until you switch on LED marked in the picture.
Use the potentiometer to set required value of spot time 0.5-5 sec.
Setting PULSE time
Press button SET until you switch on LED marked in the picture.
Use the potentiometer to set up required value of interval time between
particular 0.2-2 sec.
Setting four-stroke welding mode
Press button FNC until you switch on LED.
Mode four-stroke is adjusted.
Setting four-stroke SPOTTING
Press button FNC until you switch on two LED four-stroke and SPOTTING in
the picture.
Mode four-stroke spotting is adjusted.
Setting four-time PULSE mode
Press button FNC until you switch on two LED four-stroke and PULSE in the
pic.
Mode four-stroke pulse is adjusted.
Function MEM
(only with machines PROCESSOR)
Function enables back recall and display of last welding parameters for a
period of about 7 sec.
Press button MEM
Display will show last measured values of welding voltage and current for 7
sec. Values can be recalled repeatedly.
Function SYNERGIC
(only with machines SYNERGIC)
Function SYNERGIC simplifies operating and adjustment of welding para
-
meters. Operating staff can specify type of program through a simple setting
of gas type and wire diameter. To set welding parameters you can set simply
and easily voltage with a switch and electronics will adjust speed of wire
shift automatically.
Switching on function SYNERGIC
Press button SYN until you switch on LED SYN and LED material thickness.
Function SYNERGIC is on.
Program choice - adjustment of wire diameter and gas type
Press button SET until you switch on LED marked in the picture.
Using the potentiometer, you shall choose gas type you are going to apply
- CO
2
or Ar (marks MIX argon and CO
2
gas in ratio 18 CO
2
and the rest Ar.
EN
Summary of Contents for 305
Page 22: ... 67 ...